The rapid development of wearable and intelligent flexible devices has posed strict requirements for power sources, including excellent mechanical strength, inherent safety, high energy density, and eco-friendliness. Zn-ion batteries with aqueous quasi-solid-state electrolytes (AQSSEs) with various functional groups that contain electronegative atoms (O/N/F) with tunable electron accumulation states are considered as a promising candidate to power the flexible devices and tremendous progress has been achieved in this prospering area. Herein, this review proposes a comprehensive summary of the recent achievements using the AQSSE in flexible devices by focusing on the significance of different functional groups. The fundamentals and challenges of the ZIBs are introduced from a chemical view in the first place. Then, the mechanism behind the stabilization of the flexible ZIBs with the functionalized AQSSE is summarized and explained in detail. Then the recent progress regarding the enhanced electrochemical stability of the ZIBs with the AQSSE is summarized and classified based on the functional groups on the polymer chain. The advanced characterization methods for the AQSSE are briefly introduced in the following sections. Last but not least, current challenges and future perspectives for this promising area are provided from the authors' point of view.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/adma.202412447 | DOI Listing |
Int J Biol Macromol
December 2024
Plant Fiber Material Science Research Center, State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou 510640, PR China; Guangdong Provincial Key Laboratory of Plant Resources Biorefinery, Guangzhou 510640, PR China.
The development of flexible, intelligent, and lightweight optoelectronic devices based on flexible transparent conductive electrodes (FTCEs) utilizing silver nanowires (AgNWs) has garnered increasing attention. However, achieving low surface resistance, strong adhesion to the flexible substrate, low surface roughness, and green degradability remains a challenge. Here, a composite electrode combining natural polymer cellulose nanofibers (TCNFs) with AgNWs was prepared.
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
International and Inter-University Centre for Nanoscience and Nanotechnology (IIUCNN), Mahatma Gandhi University, Kottayam, Kerala 686 560, India; School of Energy Materials, Mahatma Gandhi University, Kottayam, Kerala 686560, India; School of Nanoscience and Nanotechnology, Mahatma Gandhi University, Kottayam, Kerala 686560, India; Department of Chemical Sciences, University of Johannesburg, P.O.Box 17011, Doornfontein, 2028 Johannesburg, South Africa; Trivandrum Engineering, Science and Technology (TrEST) Research Park, Trivandrum 695016, India. Electronic address:
Cellulose paper-based composites represent a promising and sustainable alternative for electromagnetic interference (EMI) shielding applications. Derived from renewable and biodegradable cellulose fibers, these composites are enhanced with conductive fillers namely carbon nanotubes, graphene, or metallic nanoparticles, achieving efficient EMI shielding while maintaining environmental friendliness. Their lightweight, flexible nature, and mechanical robustness make them ideal for diverse applications, including wearable electronics, flexible circuits, and green electronics.
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
College of Materials Science and Engineering, Nanjing Tech University, Nanjing 210009, China.
Conductive hydrogels have great potential for applications in flexible wearable sensors due to the combination of biocompatibility, mechanical flexibility and electrical conductivity. However, constructing conductive hydrogels with high toughness, low hysteresis and skin-like modulus simultaneously remains challenging. In the present study, we prepared a tough and conductive polyacrylamide/pullulan/ammonium sulfate hydrogel with a semi-interpenetrating network.
View Article and Find Full Text PDFInt J Med Robot
February 2025
Division of Colorectal Surgery, Department of Surgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea.
Background: Single port robotic platform offers articulation and 360° camera rotation for anorectal tumour excision in a narrow pelvic space. This study assesses the clinical usefulness and outcomes of SP robotic transanal surgery.
Methods: Nine patients who underwent transanal excision using the SP robotic platform were included.
ACS Appl Mater Interfaces
December 2024
Advanced Research Institute of Multidisciplinary Sciences, Beijing Institute of Technology, Beijing 100081, China.
Humidity sensors have been widely used to monitor humidity in daily life, agriculture fields, and so on. However, conventional sensors are not suitable for wearable devices because of their large dimensions and rigid substrates. Hence, we report a fast response, highly sensitive, and fully flexible humidity sensor on a PI substrate based on the composite material of reduced graphene oxide (rGO)/MoS, with a response time of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!