Enzyme-modified Pt nanoelectrodes for glutamate detection.

Faraday Discuss

Chan Zuckerberg Biohub Chicago, USA.

Published: October 2024

We present here a glutamate oxidase (GluOx)-modified platinum (Pt) nanoelectrode with a planar geometry for glutamate detection. The Pt nanoelectrode was characterized using electrochemistry and scanning electron microscopy (SEM). The radius of the Pt nanoelectrode measured using SEM is ∼210 nm. GluOx-modified Pt nanoelectrodes were generated by dip coating GluOx on the Pt nanoelectrode in a solution of 0.9% (wt%) bovine serum albumin (BSA), 0.126% (wt%) glutaraldehyde, and 100 U mL GluOx. An increase in current was observed at +0.7 V Ag/AgCl/1 M KCl with adding increasing concentrations of glutamate. Two-sample -test results showed that there is a significant difference for current at +0.7 V between the blank and the added lowest glutamate concentration, as well as between adjacent glutamate concentrations, confirming that the increase in current is related to the increased glutamate concentration. The experimental current-concentration curve of glutamate detection fitted well to the theoretical Michaelis-Menten curve. At the low concentration range (50 μM to 200 μM), a linear relationship between the current and glutamate concentration was observed. The Michaelis-Menten constants of and were calculated to be 1.093 pA and 0.227 mM, respectively. Biosensor efficiency (the ratio of glutamate sensitivity to HO sensitivity) is calculated to be 57.9%. Enz (/HO sensitivity, an indicator of the amount of enzyme loaded on the electrode) of the GluOx-modified Pt nanoelectrode is 0.243 mM. We further compared the sensitivity of a GluOx-modified Pt nanoelectrode with a GluOx-modified carbon fiber microelectrode (7 μm diameter and a sensing length of ∼350 μm). Glutamate detection on the GluOx-modified carbon fiber microelectrode fitted well to a Michaelis-Menten like response. Based on the fitting, the GluOx-modified carbon fiber microelectrode exhibited an of 0.689 nA and a of 301.2 μM towards glutamate detection. The best linear range of glutamate detection on the GluOx-modified carbon fiber microelectrode is from 50 μM to 150 μM glutamate. The GluOx-modified carbon fiber microelectrode exhibited a higher potential requirement for glutamate detection compared to the GluOx-modified Pt nanoelectrode.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d4fd00138aDOI Listing

Publication Analysis

Top Keywords

glutamate detection
28
gluox-modified carbon
20
carbon fiber
20
fiber microelectrode
20
glutamate
15
glutamate concentration
12
gluox-modified nanoelectrode
12
μm glutamate
12
gluox-modified
10
increase current
8

Similar Publications

Introduction: The genetic complexity of Plasmodium falciparum is contributory to the emergence of drug resistant-parasites. Intermittent preventive treatment of malaria in pregnancy with sulfadoxine-pyrimethamine (IPTp-SP) in malaria endemic settings is recommended by WHO. This study evaluated the prevalence of Plasmodium falciparum multidrug resistance-1 gene (Pfmdr-1), genetic diversity of merozoite surface proteins (msp-1, msp-2) and glutamate-rich protein (glurp) among pregnant women with sub-patent parasitaemia from southwest Nigeria.

View Article and Find Full Text PDF

: Paraneoplastic neurological syndromes (PNSs) are rare conditions characterized by immune-mediated pathogenesis, frequently associated with the presence of a neoplasm. Although a single antineuronal antibody mediates a specific syndrome, atypical manifestations mediated by the same antibody have been described. : The aim of this study was to report on an atypical case of PNS with dual positivity for anti-GAD65 and anti-CRMP5/CV2 antibodies, simultaneously characterized by cognitive decline associated with progressive ataxia and parkinsonism.

View Article and Find Full Text PDF

: The rapid development of refrigerated transportation technology for fresh vegetables has extended their shelf life. Some vegetables may appear undamaged on the surface, but their freshness may have decreased, often resulting in the phenomenon of passing off inferior vegetables as good. It is very important to establish a detection method for identifying and assessing the freshness of vegetables.

View Article and Find Full Text PDF

Objective: The study investigates whether the expression and function of ENT1 can be regulated by inhibiting the JNK signaling pathway, thereby altering the levels of extracellular adenosine and glutamate in neurons, and subsequently affecting the progression of epilepsy.

Methods: The adult male SD rats were randomly divided into four groups: EP + SP600125 group, EP + DMSO group, EP group, and normal control group. The expression levels of ENT1, p-JNK, and JNK in the hippocampus of rats from each experimental group were detected using Western blotting technology.

View Article and Find Full Text PDF

We describe a woman with stiff-person syndrome (SPS), whose muscle spasms resulted in sequential bilateral femoral neck fractures. Orthopaedic fixation of the first fracture was complicated by increased muscle spasm, fracture nonunion and ultimately metalwork fracture. SPS was diagnosed following the fracture of the contralateral femoral neck, neurology assessment and detection of high-titre antibodies to glutamic acid decarboxylase.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!