This study provides an overview of the effect of differential item functioning (DIF) on measurement precision, test information function (TIF), and test effectiveness in computer adaptive tests (CATs). Simulated data for the study was produced and analyzed with the Rstudio. During the data generation process, item pool size, DIF type, DIF percentage, item selection method for CAT, and the test termination rules were considered changed conditions. Sample size and ability parameter distribution, Item Response Theory (IRT) model, DIF size, ability estimation method, test starting rule, and item usage frequency method regarding CAT conditions were considered fixed conditions. To examine the effect of DIF, measurement precision, TIF and test effectiveness were calculated. Results show DIF has negative effects on measurement precision, TIF, and test effectiveness. In particular, statistically significant effects of the percentage DIF items and DIF type are observed on measurement precision.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11501093PMC
http://dx.doi.org/10.1177/01466216241284295DOI Listing

Publication Analysis

Top Keywords

measurement precision
16
tif test
12
test effectiveness
12
differential item
8
item functioning
8
computer adaptive
8
dif
8
dif measurement
8
dif type
8
method cat
8

Similar Publications

Measuring low light absorption with combined uncertainty <1 per mil (‰) is crucial for many applications. Popular cavity ring-down spectroscopy can provide ultrahigh precision, below 0.01‰, but its accuracy is often worse than 5‰ due to inaccuracies in light intensity measurements.

View Article and Find Full Text PDF

Dual Open Atom Interferometry for Compact and Mobile Quantum Sensing.

Phys Rev Lett

December 2024

The Australian National University, Department of Quantum Science and Technology, Canberra, Australian Capital Territory 2601, Australia.

We demonstrate an atom interferometer measurement protocol compatible with operation on a dynamic platform. Our method employs two open interferometers, derived from the same atomic source, with different interrogation times to eliminate initial velocity dependence while retaining precision, accuracy, and long term stability. We validate the protocol by measuring gravitational tides, achieving a precision of 4.

View Article and Find Full Text PDF

Precise Measurement of the e^{+}e^{-}→D_{s}^{+}D_{s}^{-} Cross Section at Center-of-Mass Energies from Threshold to 4.95 GeV.

Phys Rev Lett

December 2024

State Key Laboratory of Particle Detection and Electronics, Beijing 100049, Hefei 230026, People's Republic of China.

Using the e^{+}e^{-} collision data collected with the BESIII detector operating at the BEPCII collider, at center-of-mass energies from the threshold to 4.95 GeV, we present precise measurements of the cross section for the process e^{+}e^{-}→D_{s}^{+}D_{s}^{-} using a single-tag method. The resulting cross section line shape exhibits several new structures, thereby offering an input for a future coupled-channel analysis and model tests, which are critical to understand vector charmonium-like states with masses between 4 and 5 GeV.

View Article and Find Full Text PDF

A comprehensive study of the angular distributions in the bottom-baryon decays Λ_{b}^{0}→Λ_{c}^{+}h^{-}(h=π,K), followed by Λ_{c}^{+}→Λh^{+} with Λ→pπ^{-} or Λ_{c}^{+}→pK_{S}^{0} decays, is performed using a data sample of proton-proton collisions corresponding to an integrated luminosity of 9  fb^{-1} collected by the LHCb experiment at center-of-mass energies of 7, 8, and 13 TeV. The decay parameters and the associated charge-parity (CP) asymmetries are measured, with no significant CP violation observed. For the first time, the Λ_{b}^{0}→Λ_{c}^{+}h^{-} decay parameters are measured.

View Article and Find Full Text PDF

Proximity Ligation Assay to Study Oncogene-Derived Transcription-Replication Conflicts.

J Vis Exp

January 2025

Institute of Biochemistry and Molecular Biology, Hengyang Medical School, University of South China; National Health Commission Key Laboratory of Birth Defect Research and Preventio, Hunan Provincial Maternal and Child Health Care Hospital;

Both DNA replication and RNA transcription utilize genomic DNA as their template, necessitating spatial and temporal separation of these processes. Conflicts between the replication and transcription machinery, termed transcription-replication conflicts (TRCs), pose a considerable risk to genome stability, a critical factor in cancer development. While several factors regulating these collisions have been identified, pinpointing primary causes remains difficult due to limited tools for direct visualization and clear interpretation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!