A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Design of a Conformal Ablation System Based on Independent Control of Radiofrequency Electrode Arrays]. | LitMetric

[Design of a Conformal Ablation System Based on Independent Control of Radiofrequency Electrode Arrays].

Zhongguo Yi Liao Qi Xie Za Zhi

School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030.

Published: September 2024

This study aims to develop an independent control system for radiofrequency electrode arrays, intended for the conformal ablation of unwanted tissues. Unlike traditional single radiofrequency voltage applications, this study employs high-frequency transformer isolation and radiofrequency load matching technologies to divide the radiofrequency signal source into eight independent groups. Each group operates at the same phase and frequency but with different voltage values. Experimental results indicate that the designed system can independently output various combinations of radiofrequency signals. The actual output voltage has a relative error controlled within 6%, the frequency error is less than 0.5%, and the phase difference among the groups is less than 1°. In the biomimetic tissue heating experiments, it is found that by controlling the voltage of each electrode within the electrode array, ablation of different shapes can be achieved, and the ablation depth is positively correlated with the applied radiofrequency voltage.

Download full-text PDF

Source
http://dx.doi.org/10.12455/j.issn.1671-7104.240171DOI Listing

Publication Analysis

Top Keywords

conformal ablation
8
independent control
8
radiofrequency electrode
8
radiofrequency voltage
8
radiofrequency
7
voltage
5
[design conformal
4
ablation
4
ablation system
4
system based
4