A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Parameter dependence of depth and lateral resolution of transmission Kikuchi diffraction. | LitMetric

Parameter dependence of depth and lateral resolution of transmission Kikuchi diffraction.

Ultramicroscopy

School of Aerospace, Mechanical and Mechatronic Engineering, University of Sydney, Camperdown, NSW 2006, Australia; Australian Centre for Microscopy and Microanalysis, University of Sydney, Camperdown, NSW 2006, Australia. Electronic address:

Published: December 2024

The spatial resolution of transmission Kikuchi diffraction (TKD) depends on experimental parameters such as atomic number, accelerating voltage, sample backtilt and thickness. In this work, the dependence of spatial resolution on these parameters is explored by using bilayered coarse-grained/nanocrystalline samples to determine the depth resolution. Digital image correlation of the Kikuchi patterns across grain boundaries is used to measure the lateral resolution. The depth resolutions of TKD in aluminium, copper and platinum at 30 kV for an untilted sample were 80, 32 and 14 nm respectively. These worsened with increasing sample backtilt and slightly improved with decreasing accelerating voltage. The best physical lateral resolution obtained was 6 nm, at 30 keV in a 41 nm thick aluminium sample with no backtilt. The lateral resolution worsened with increasing sample thickness and backtilt, contrasting with some previous reports. Accelerating voltage and atomic number did not have a significant impact on the measured lateral resolution within the scatter in the data.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2024.114062DOI Listing

Publication Analysis

Top Keywords

lateral resolution
20
accelerating voltage
12
sample backtilt
12
resolution
8
resolution transmission
8
transmission kikuchi
8
kikuchi diffraction
8
spatial resolution
8
atomic number
8
worsened increasing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!