In chromatic confocal line sensors, calibration is usually divided into peak extraction and wavelength calibration. In previous research, the focus was mainly on peak extraction. In this paper, a kernel-based algorithm is proposed to deal with wavelength calibration, which corresponds to the mapping relationship between peaks (i.e., the wavelengths) in image space and profiles in physical space. The primary component of the mapping function is depicted using polynomial basis functions, which are distinguished along various dispersion axes. Considering the unknown distortions resulting from field curvature, sensor fabrication and assembly, and even the inherent complexity of dispersion, a typical kernel trick-based nonparametric function element is introduced here, predicated on the notion that similar processes conducted on the same sensor yield comparable distortions.To ascertain the performance with and without the kernel trick, we carried out wavelength calibration and groove fitting on a standard groove sample processed via glass grinding and with a reference depth of 66.14 μm. The experimental results show that depths calculated by the kernel-based calibration algorithm have higher accuracy and lower uncertainty than those ascertained using the conventional polynomial algorithm. As such, this indicates that the proposed algorithm provides effective improvements.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11510888 | PMC |
http://dx.doi.org/10.3390/s24206649 | DOI Listing |
Sensors (Basel)
December 2024
Department of Electrical and Computer Engineering, University of Missouri, Columbia, MO 65211, USA.
Multi-modal systems extract information about the environment using specialized sensors that are optimized based on the wavelength of the phenomenology and material interactions. To maximize the entropy, complementary systems operating in regions of non-overlapping wavelengths are optimal. VIS-IR (Visible-Infrared) systems have been at the forefront of multi-modal fusion research and are used extensively to represent information in all-day all-weather applications.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
December 2024
School of Pharmaceutical Sciences, Lovely Professional University, Phagwara, Punjab, India; Faculty of Health, Australian Research Centre in Complementary and Integrative Medicine, University of Technology Sydney, Ultimo, NSW 2007, Australia. Electronic address:
Xanthohumol(Xn) is isolated from female inflorescences of Humulus lupulus. It has been discovered that Xn and its formulation are useful in the treatment of cancer. As this bioactive compound has medicinal importance, hence, a novel, precise, and sensitive HPLC method should be developed.
View Article and Find Full Text PDFNat Commun
January 2025
State Key Laboratory for Extreme Photonics and Instrumentation, Center for Optical & Electromagnetic Research, College of Optical Science and Engineering, International Research Center for Advanced Photonics (Haining), Zhejiang University, Hangzhou, China.
Silicon photonic signal processors promise a new generation of signal processing hardware with significant advancements in processing bandwidth, low power consumption, and minimal latency. Programmable silicon photonic signal processors, facilitated by tuning elements, can reduce hardware development cycles and costs. However, traditional programmable photonic signal processors based on optical switches face scalability and performance challenges due to control complexity and transmission losses.
View Article and Find Full Text PDFIt can be difficult to employ optical techniques for analyzing biological structures smaller than or comparable to the wavelength of light, such as extracellular vesicles or some types of bacteria. Biological light scattering spectroscopy (LSS), developed to address this problem, has been successfully used for characterizing tissue on cellular and subcellular scales. At the same time, calibration with a reference sample of known optical properties can complicate LSS measurements.
View Article and Find Full Text PDFJ Biomed Opt
June 2024
Tyndall National Institute, Biophotonics@Tyndall, Cork, Ireland.
Significance: Dynamic phantoms capable of changing optical properties by control are essential for standardizing and calibrating spectroscopy systems such as the pulse oximeter. However, current liquid dynamic phantoms containing human blood have a short shelf life and require complex experimental setups. Some solid dynamic phantoms are influenced by the angular-dependent performance of the liquid crystal display (LCD), some have a low spatial resolution, and some have slow control of optical properties.