A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Integrated Precision High-Frequency Signal Conditioner for Variable Impedance Sensors. | LitMetric

Integrated Precision High-Frequency Signal Conditioner for Variable Impedance Sensors.

Sensors (Basel)

Faculty of Technical Sciences, University of Novi Sad, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia.

Published: October 2024

In this paper, a signal conditioner intended for use in variable impedance sensors is presented. First, an inductive linear displacement sensor design is described, and the signal conditioner discrete realization is presented. Second, based on this system's requirements, the integrated conditioner is proposed. The conditioner comprises an amplifier, a tunable band-pass filter, and a precision high-frequency AC-DC converter. It is designed in a low-cost AMS 0.35 µm CMOS process. The presented conditioner measures the sensor's impedance magnitude by using a simplified variation of the sensor voltage and current vector measurement. It can be used for the real-time measurement of fast sensors, having small output impedance. The post-layout simulation results show that the integrated conditioner has an inductance measurement range from 10 nH to 550 nH with a nonlinearity of 1.2%. The operating frequency in this case was 8 MHz, but the circuit can be easily adjusted to different operating frequencies (due to the tunable filter). The designed IC area is 500 × 330 μm, and the total power consumption is 93.8 mW.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11511152PMC
http://dx.doi.org/10.3390/s24206501DOI Listing

Publication Analysis

Top Keywords

signal conditioner
12
precision high-frequency
8
variable impedance
8
impedance sensors
8
integrated conditioner
8
conditioner
7
integrated precision
4
high-frequency signal
4
conditioner variable
4
impedance
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!