A two-level three-factor factorial design experiment was conducted to study the influences of three critical specimen preparation parameters on the measurement results of bitumen by a dynamic shear rheometer (DSR). The investigated factors were (1) the pre-heating temperature (HT) for manufacturing the specimen, (2) the bonding temperature (BT) onto the rheometer, and (3) the trimming (Trim) operation for preparing the specimen after bonding. The analysed data were the measured shear modulus |*|, phase angle , and the characteristic temperatures of bitumen's specific stiffness with corresponding phase angle according to the European standard EN 14770:2023. Five types of bitumen were tested, including three penetration grades and two modified bitumen specimens (with polymer and wax additives). In addition, a repeatability evaluation of the test results was conducted. We found that the trimming operation for preparing the specimen has a noticeable impact when using smaller plates (PP08) for the DSR measurement. At higher test temperatures when using larger plates (PP25), the trimming operation does not significantly impact the measured parameters, in contrast to the HT and BT. Except for bitumen type 70/100, modified binders are more susceptible to variation in the analysed parameters than unmodified ones. The three-way interaction Trim:BT:HT tends to cause relatively little variation in measured data. Interactions between two factors Trim:BT, Trim:HT, and BT:HT contribute more to the fluctuation in value than in and |*|. The variation employed in this study affects the test repeatability of wax-modified bitumen significantly; however, for unmodified binders the repeatability of and are within 0.4-2.1 °C and 0.3-3.1°, respectively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11509560PMC
http://dx.doi.org/10.3390/ma17205117DOI Listing

Publication Analysis

Top Keywords

specimen preparation
8
factorial design
8
specimen bonding
8
operation preparing
8
preparing specimen
8
phase angle
8
trimming operation
8
bitumen
6
assessing specimen
4
preparation methods
4

Similar Publications

Environmental changes, such as applied medication, nutrient depletion, and accumulation of metabolic residues, affect cell culture activity. The combination of these factors reflects on the local temperature distribution and local oxygen concentration towards the cell culture scaffold. However, determining the temporal variation of local temperature, independent of local oxygen concentration changes in biological specimens, remains a significant technological challenge.

View Article and Find Full Text PDF

Background/objectives: Mummy studies allow to reconstruct the characteristic of a population in a specific spatiotemporal context, in terms of living conditions, pathologies and death. Radiology represents an efficient diagnostic technique able to establish the preservation state of mummified organs and to estimate the patient's pathological conditions. However, the radiological approach shows some limitations.

View Article and Find Full Text PDF

This study evaluated the microbial growth profile of subgingival multispecies biofilm on 3D-printable resin-based composites (PRBCs). A 96-well cell plate cultivated a 39-species biofilm associated with periodontitis over 7 days. Cylindrical specimens with 12 mm high and 3 mm diameters were prepared by the PRBC group (Cosmos Temp-Yller; Prizma 3D Bio Crown; Prizma 3D Bio Prov) and an acrylic resin as control.

View Article and Find Full Text PDF

Evaluation of Internal and Marginal Accuracy (Trueness and Precision) of Laminates Using DLP Printing and Milling Methods.

Biomimetics (Basel)

January 2025

Department of Healthcare Sciences, Faculty of Dental Laboratory Science and Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.

This study evaluated the internal and marginal accuracy (trueness and precision) of zirconia laminate veneers fabricated using the DLP printing and milling method, employing 3D analysis software program. The maxillary central incisor tooth of a typodont model was prepared by a dentist and scanned using a desktop scanner. An anatomical zirconia laminate was designed using computer-aided design (CAD) software and saved in a standard tessellation language (STL) format.

View Article and Find Full Text PDF

Creation and long-term in vitro maintenance of valuable genotype collection is one of the modern approach to conservation of valuable gene pool of woody plants. However, during prolonged cultivation, genetic variability of cells and tissues may accumulate and lead to the loss of valuable characteristics of parental plants. It is therefore important to assess the genetic (including cytogenetic) stability of collection clones.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!