: In electrophysiological procedures, multiple punctures on the femoral vein can be necessary depending on the number of catheters required. The femoral vein is typically located indirectly by using its anatomical relationship to the artery as a reference. However, this conventional approach can lead to significant complications, including bleeding, peri-interventional transfusion, pseudoaneurysms, or arteriovenous fistulas. Despite these risks, there is limited evidence comparing the safety of ultrasound-guided venipuncture versus the conventional technique in electrophysiological procedures. : This study aimed to evaluate the impact of ultrasound-guided venipuncture on vascular access complications in electrophysiological procedures and to identify associated risk factors. Methods: In this single-center trial, patients scheduled for electrophysiological procedures at Ulm University Heart Center, Germany, were enrolled between November 2021 and October 2023. Venipuncture in the groin was performed using either the conventional or an ultrasound-guided approach. The primary composite endpoint was defined as peri-interventional major vascular access complications (Bleeding Academic Research Consortium (BARC) ≥2 bleeding, pseudoaneurysms, arteriovenous fistulas, and peri-interventional transfusion) and minor complications (BARC 1). : A total of 1370 patients were included: 749 in the conventional group and 621 in the ultrasound group. The primary endpoint was achieved in 19.2% of the conventional group and 12.1% of the ultrasound group ( < 0.001). An increased sheath diameter and a higher number of venous accesses were identified as risk factors for the primary endpoint. : Ultrasound guidance for venous groin puncture in electrophysiological procedures reduces access-related complications, supporting its use with careful attention to sheath size and number.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11504843PMC
http://dx.doi.org/10.3390/biomedicines12102375DOI Listing

Publication Analysis

Top Keywords

electrophysiological procedures
24
complications electrophysiological
8
femoral vein
8
peri-interventional transfusion
8
pseudoaneurysms arteriovenous
8
arteriovenous fistulas
8
ultrasound-guided venipuncture
8
vascular access
8
access complications
8
risk factors
8

Similar Publications

Electrical excitability of neuronal networks based on the voltage threshold of electrical stimulation.

Sci Rep

December 2024

State Key Laboratory of Digital Medical Engineering, Southeast University, Nanjing, 210096, China.

Microelectrode arrays (MEAs) have been widely used in studies on the electrophysiological features of neuronal networks. In classic MEA experiments, spike or burst rates and spike waveforms are the primary characteristics used to evaluate the neuronal network excitability. Here, we introduced a new method to assess the excitability using the voltage threshold of electrical stimulation.

View Article and Find Full Text PDF

Effect of selective dorsal rhizotomy on bladder dysfunction in children with spastic cerebral palsy.

Sci Rep

December 2024

Department of Neurosurgery, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, No.1678, Dongfang Road, Pudong District, Shanghai, China.

This study investigated the prevalence and severity of lower urinary tract symptoms (LUTS) in children with spastic cerebral palsy (SCP) and evaluated the effect of selective dorsal rhizotomy (SDR) in alleviating these symptoms. The study also explored the correlation between postoperative LUTS improvement and intraoperative electrophysiological findings. Prospective data were collected from a consecutive cohort of 247 children with SCP who underwent SDR and were retrospectively analyzed.

View Article and Find Full Text PDF

Background: Patients with disorders of consciousness (DOC) undergoing spinal cord stimulation (SCS) for arousal treatment require an assessment of their conscious state before and after the procedure. This is typically evaluated using behavioral scales (CRS-R), but this method can be influenced by the subjectivity of the physician. Event-related potentials (ERP) and EEG power spectrum are associated with the recovery of consciousness.

View Article and Find Full Text PDF

Time-varying changes in whole-brain connectivity patterns, or connectome state dynamics, are a prominent feature of brain activity with broad functional implications. While infraslow (<0.1 Hz) connectome dynamics have been extensively studied with fMRI, rapid dynamics highly relevant for cognition are poorly understood.

View Article and Find Full Text PDF

Background: Lambert-Eaton myasthenic syndrome (LEMS) is an autoimmune disorder of the presynaptic neuromuscular junction associated with antibody mediated dysfunction of voltage-gated calcium channels (VGCCs). LEMS can exist as a paraneoplastic syndrome, paraneoplastic-LEMS (P-LEMS), when associated with tumors, most commonly, small cell lung carcinoma (SCLC) or as a non-paraneoplastic condition (NP-LEMS) when no malignancies are detected.

Methods: A retrospective chart review was conducted in 3 tertiary hospitals in Saudi Arabia for patients diagnosed with LEMS between January 2010 and January 2020.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!