A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Delayed three-dimensional inversion recovery-prepared fast low-angle shot for airway imaging in children: More than myocardial fibrosis assessment. | LitMetric

Delayed three-dimensional inversion recovery-prepared fast low-angle shot for airway imaging in children: More than myocardial fibrosis assessment.

J Cardiovasc Magn Reson

Department of Diagnostic and Interventional Radiology, Hospital for Sick Children, Toronto, Ontario, Canada; Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada. Electronic address:

Published: December 2024

AI Article Synopsis

  • A study was conducted to assess the effectiveness of a specific MRI technique (delayed 3D IR FLASH) in evaluating the lower airways of children during routine cardiovascular magnetic resonance imaging.
  • The study included 180 pediatric patients, with a high image quality rating and visibility of lower airways; around 21% of patients showed lower airway abnormalities, particularly among those with congenital heart disease.
  • The results suggest that this MRI method is highly reliable and effective for viewing lower airway anatomy, enhancing the potential for identifying issues in children with heart conditions.

Article Abstract

Background: To investigate the ability of a delayed respiratory-navigated, electrocardiographically-gated three-dimensional inversion recovery-prepared fast low-angle shot (3D IR FLASH) sequence to evaluate the lower airways in children undergoing routine cardiovascular magnetic resonance (CMR).

Methods: This retrospective study included pediatric patients (0-18 years) who underwent clinical CMR where a delayed 3D IR FLASH sequence was performed between July 2020 and April 2021. The airway image quality and extent of lower airway visibility were graded by two blinded readers using a four-point ordinal scale (0-3). Lower airway anatomical variants and abnormalities were recorded.

Results: One hundred and eighty patients were included with a median age of 11.7 (4.6-15.3) years. Fifty-one of 180 (28%) were under general anesthesia. Overall, the median grading of airway image quality was 3 (2-3) and the extent of lower airway visibility was 3 (3-3). Interrater agreement was almost perfect (κ = 0.867 and κ = 0.956, respectively). Image quality correlated with extent of lower airway visibility (r = 0.62, p < 0.01). Delayed 3D IR FLASH was able to characterize the segmental bronchi in 137/180 (76%) and lobar bronchi in 172/180 (96%) of patients. Lower airway abnormalities were identified in 37/180 (21%) of patients and 33/129 (26%) with congenital heart disease (CHD). Identified abnormalities included tracheobronchial branching anomalies in 6/180 (3%), abnormal tracheobronchial situs in 6/180 (3%), and extrinsic vascular compression in 25/180 (14%).

Conclusion: Delayed 3D IR FLASH has excellent performance for evaluation of the lower airway anatomy and can simultaneously assess for myocardial late gadolinium enhancement. Lower airway abnormalities are not infrequently seen in children undergoing routine CMR for CHD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11655686PMC
http://dx.doi.org/10.1016/j.jocmr.2024.101110DOI Listing

Publication Analysis

Top Keywords

lower airway
16
image quality
12
extent lower
12
airway visibility
12
three-dimensional inversion
8
inversion recovery-prepared
8
recovery-prepared fast
8
fast low-angle
8
low-angle shot
8
flash sequence
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!