Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background/objectives: This study aimed to evaluate the effect of ProDesign Logic files 45.01 and 50.01 on apical foramen wear and shape transformation after foraminal enlargement at tooth length (TL) and 1 mm beyond.
Methods: Sixty freshly extracted single-rooted lower human premolars teeth were distributed randomly into five groups ( = 12): Group 1 (40.05 WL) (control): No foraminal enlargement, Group 2 (45.01 TL): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at TL; Group 3 (45.01 TL + 1): Specimens underwent foraminal enlargement with 45.01 Prodesign Logic file at 1 mm beyond TL; Group 4 (50.01 TL): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at TL; Group 5 (50.01 TL + 1): Specimens underwent foraminal enlargement with 50.01 Prodesign Logic file at 1 mm beyond TL. Scanning electron microscopy was used to evaluate apical foramen variations and shape alterations. Data were analyzed by Student's -test, Kruskal-Wallis, and Mann-Whitney test.
Results: Significant differences ( < 0.01) were observed among all tested groups compared to the control group in terms of the average worn area of the apical foramen. Foraminal enlargement led to significant shape transformation, resulting in round-shaped foramina.
Conclusion: ProDesign Logic 45.01 and 50.01 files at TL causes notable wear and round-shaped foramina.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11506177 | PMC |
http://dx.doi.org/10.3390/dj12100330 | DOI Listing |