A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bionic Design and Adsorption Performance Analysis of Vacuum Suckers. | LitMetric

Bionic Design and Adsorption Performance Analysis of Vacuum Suckers.

Biomimetics (Basel)

College of Biological and Agricultural Engineering, Jilin University, Changchun 130022, China.

Published: October 2024

This study addresses the problem that the traditional method is not effective in improving the adsorption performance of vacuum suckers. From the perspective of bionics, the adsorption performance of bionic suckers based on the excellent adsorption of the abalone abdominal foot was studied. A bionic sucker was designed by extracting the sealing ring structure of the abdominal foot tentacle. The bionic sucker was subjected to tensile experiments using an orthogonal experimental design, and the adsorption of the bionic sucker was simulated and analyzed to explore its adsorption mechanism. The results show that the primary and secondary factors affecting the adsorption of the sucker are the number of sealing rings, the width of sealing rings and the spacing of sealing rings. At 60% vacuum, the bionic sucker with two sealing rings, a 1.5 mm sealing ring width and 3 mm sealing ring spacing has the largest adsorption force, and its maximum adsorption force is 15.8% higher than that of the standard sucker. This study shows that the bionic sucker design can effectively improve the adsorption performance of the sucker. The bionic sucker had a different stress distribution on the sucker bottom, which resulted in greater Mises stress in the sealing ring and the surrounding area, while the Mises stress in the central area of the sucker was smaller.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11506676PMC
http://dx.doi.org/10.3390/biomimetics9100623DOI Listing

Publication Analysis

Top Keywords

bionic sucker
24
adsorption performance
16
sealing ring
16
sealing rings
16
sucker
11
adsorption
10
bionic
8
design adsorption
8
vacuum suckers
8
abdominal foot
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!