Background/objectives: Photoplethysmography (PPG) signals, which measure blood volume changes through light absorption, are increasingly used for non-invasive cardiovascular disease (CVD) detection. Analyzing PPG signals can help identify irregular heart patterns and other indicators of CVD.
Methods: This research involves a total of 41 subjects sourced from the CapnoBase database, consisting of 21 normal subjects and 20 CVD cases. In the initial stage, heuristic optimization algorithms, such as ABC-PSO, the Cuckoo Search algorithm (CSA), and the Dragonfly algorithm (DFA), were applied to reduce the dimension of the PPG data. Next, these Dimensionally Reduced (DR) PPG data are then fed into various classifiers such as Linear Regression (LR), Linear Regression with Bayesian Linear Discriminant Classifier (LR-BLDC), K-Nearest Neighbors (KNN), PCA-Firefly, Linear Discriminant Analysis (LDA), Kernel LDA (KLDA), Probabilistic LDA (ProbLDA), SVM-Linear, SVM-Polynomial, and SVM-RBF, to identify CVD. Classifier performance is evaluated using Accuracy, Kappa, MCC, F1 Score, Good Detection Rate (GDR), Error rate, and Jaccard Index (JI).
Results: The SVM-RBF classifier for ABC PSO dimensionality reduced values outperforms other classifiers, achieving the highest accuracy of 95.12% along with the minimum error rate of 4.88%. In addition to that, it provides an MCC and kappa value of 0.90, a GDR and F1 score of 95%, and a Jaccard Index of 90.48%.
Conclusions: This study demonstrated that heuristic-based optimization and machine learning classification of PPG signals are highly effective for the non-invasive detection of cardiovascular disease.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11507182 | PMC |
http://dx.doi.org/10.3390/diagnostics14202287 | DOI Listing |
Front Public Health
January 2025
Department of Computer Science, College of Engineering and Computer Science, Jazan University, Jazan, Saudi Arabia.
Introduction: The growing demand for real-time, affordable, and accessible healthcare has underscored the need for advanced technologies that can provide timely health monitoring. One such area is predicting arterial blood pressure (BP) using non-invasive methods, which is crucial for managing cardiovascular diseases. This research aims to address the limitations of current healthcare systems, particularly in remote areas, by leveraging deep learning techniques in Smart Health Monitoring (SHM).
View Article and Find Full Text PDFJ Biophotonics
January 2025
Department of Emergency, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China.
The brain, as a vital part of central nervous system, receives approximately 25% of body's blood supply, making accurate monitoring of cerebral blood flow essential. While fNIRS is widely used for measuring brain physiology, complex tissue structure affects light intensity, spot size, and detection accuracy. Many studies rely on simulations with limited experimental validation.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Faculty of Sciences, University of Coimbra, Palacio de las Escuelas 3004-531, Coimbra, 3004-504, PORTUGAL.
Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.
Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.
Physiol Meas
January 2025
Faculty of Sciences, University of Coimbra, Palacio de las Escuelas 3004-531, Coimbra, 3004-504, PORTUGAL.
Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.
Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.
Sensors (Basel)
December 2024
Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.
Photoplethysmography is a widely used optical technique to extract physiological information non-invasively. Despite its large use and adoption, multiple factors influence the signal shape and quality, including the instrumentation used. This work analyzes the variability of the DC component of the PPG signal at three source-detector distances (6 mm, 9 mm, and 12 mm) using green, red, and infrared light and four photodiodes per distance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!