Comparative evaluation of PCR and loop-mediated isothermal amplification (LAMP) assays for detecting in poultry.

N Z Vet J

School of Agricultural, Environmental and Veterinary Sciences, Charles Sturt University, Wagga Wagga, Australia.

Published: October 2024

Aims: To develop a colourimetric loop-mediated isothermal amplification (LAMP) assay for the detection of in clinical poultry samples and compare the performance of this assay with PCR. A secondary aim was to evaluate a simple DNA extraction method that could enable LAMP-based testing in the field without the need for specialised laboratory equipment.

Methods: Primer sets for both LAMP and PCR were designed to amplify the gene of DNA was extracted from 12 isolates using a commercial extraction kit, and subjected to analysis using both LAMP and PCR. The analytical specificity of the LAMP assay was evaluated by testing it against a panel of 12 unrelated bacterial species, and the analytical sensitivity (limit of detection) was determined through testing of serial dilutions of the target DNA and compared to that of PCR. Subsequently, cloacal swabs (n = 40) from a commercial turkey flock were subjected to analysis using both LAMP and PCR assays, using a rapid DNA extraction method and a commercial extraction kit. Clinical sensitivity and specificity of the LAMP assay were calculated in comparison to PCR.

Results: A single DNA fragment of the expected size (∼ 200 base pairs), was amplified by PCR from 12 isolates, which were also all positive by the LAMP assay. The identity of all PCR amplicons was confirmed by sequencing. Both PCR and LAMP showed similar analytical sensitivity, with a LOD of 20 pg of target DNA. As neither PCR nor LAMP assays produced positive results with 12 non-related bacterial species, the analytical specificity was assessed as 100%. However, LAMP demonstrated lower clinical specificity (94.74%) compared to PCR (100%) when 40 clinical samples were tested. None of the DNA samples extracted using the simplified DNA extraction method were amplified by either LAMP or PCR.

Conclusion: The LAMP assay developed in this study exhibits comparable performance to PCR in detecting .

Clinical Relevance: The use of a rapid and portable DNA extraction method, in conjunction with LAMP assays, could create opportunities for point-of-care testing for fowl cholera in field settings.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00480169.2024.2417921DOI Listing

Publication Analysis

Top Keywords

lamp assay
20
dna extraction
16
extraction method
16
lamp
14
pcr
12
lamp assays
12
lamp pcr
12
dna
9
loop-mediated isothermal
8
isothermal amplification
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!