Background:  Autoimmune gastritis (AIG), distinct from Helicobacter pylori-associated atrophic gastritis (HpAG), is underdiagnosed due to limited awareness. This multicenter study aimed to develop a novel endoscopic artificial intelligence (AI) system for assisting in AIG diagnosis.

Methods:  Patients diagnosed with AIG, HpAG, or nonatrophic gastritis (NAG), were retrospectively enrolled from six centers. Endoscopic images with relevant demographic and medical data were collected for development of the AI-assisted system based on a multi-site feature fusion model. The diagnostic performance of the AI model was evaluated in internal and external datasets. Endoscopists' performance with and without AI support was tested and compared using Mann-Whitney U test. Heatmap analysis was performed to interpret AI model outputs.

Results:  18 828 endoscopy images from 1070 patients (294 AIG, 386 HpAG, 390 NAG) were collected. On testing datasets, AI identified AIG with 96.9 % sensitivity, 92.2 % specificity, and area under the receiver operating characteristic curve (AUROC) of 0.990 (internal), and 90.3 % sensitivity, 93.1 % specificity, and AUROC of 0.973 (external). The performance of AI (sensitivity 91.3 %) was comparable to that of experts (87.3 %) and significantly outperformed nonexperts (70.0 %;  = 0.01). With AI support, the overall performance of endoscopists was improved (sensitivity 90.3 % [95 %CI 86.0 %-93.2 %] vs. 78.7 % [95 %CI 73.6 %-83.2 %];  = 0.008). Heatmap analysis revealed consistent focus of AI on atrophic areas.

Conclusions:  This novel AI system demonstrated expert-level performance in identifying AIG and enhanced the diagnostic ability of endoscopists. Its application could be useful in guiding biopsy sampling and improving early detection of AIG.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-2451-3071DOI Listing

Publication Analysis

Top Keywords

novel endoscopic
8
endoscopic artificial
8
artificial intelligence
8
intelligence system
8
multicenter study
8
heatmap analysis
8
aig
7
performance
5
system
4
system assist
4

Similar Publications

Introduction: The performance of a high quality esophagogastroduodenoscopy (EGD) is dependent on the mucosal cleanliness. Recently, the Polprep: Effective Assessment of Cleanliness in EGD (PEACE) scale was created to assess the degree of mucosal cleanliness during EGD. The aim of this study was to validate this scoring system in a cohort of international endoscopists.

View Article and Find Full Text PDF

Background: Cancer remains a leading cause of morbidity and mortality worldwide. Traditional treatments like chemotherapy and radiation often result in significant side effects and varied patient outcomes. Immunotherapy has emerged as a promising alternative, harnessing the immune system to target cancer cells.

View Article and Find Full Text PDF

Background: Endoscopic retrograde cholangiopancreatography is a challenging procedure involving bile duct cannulation. Despite the development of several cannulation devices, none have effectively facilitated the procedure.

Aim: To evaluate the efficacy of a recently developed catheter for bile duct cannulation.

View Article and Find Full Text PDF

Novel approach to managing two enormous bezoars with successive snare-tip electrocautery: A case report.

World J Gastrointest Endosc

January 2025

Division of Gastroenterology and Hepatology, Department of Internal Medicine, Lukang Christian Hospital, Changhua 505002, Taiwan.

Background: Gastric bezoars are indigestible masses that can lead to gastrointestinal obstruction and ulceration. Standard treatments include endoscopic mechanical lithotripsy with a polypectomy snare and Coca-Cola dissolution therapy or a combination of both approaches. However, giant bezoars frequently require multiple treatment sessions and extended hospital stays.

View Article and Find Full Text PDF

This article comments on the article by Du , who conducted a randomized controlled trial aiming at evaluating the effectiveness of a novel spray flushing system in cleaning flexible endoscopes while minimizing damage to the working channels. We share our perspective on the importance of improving endoscope reprocessing methods. The findings highlight the spray flushing system's capacity to improve cleaning efficacy while minimizing damage, suggesting that it might be important in enhancing endoscope reprocessing procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!