A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Construction of a ratiometric electrochemical sensor for Bisphenol A detection by coupling nonionic surfactant-decorated conductive carbon black with ferricyanide probe. | LitMetric

Construction of a ratiometric electrochemical sensor for Bisphenol A detection by coupling nonionic surfactant-decorated conductive carbon black with ferricyanide probe.

Talanta

Key Laboratory of Science and Technology of Eco-Textiles, Ministry of Education, College of Chemistry and Chemical Engineering, Donghua University, Shanghai, 201620, China; National Innovation Center of Advanced Dyeing & Finishing Technology, Tai'an, Shandong, 271000, China. Electronic address:

Published: February 2025

In this work, a novel ratiometric electrochemical sensor for bisphenol A (BPA) detection was facilely constructed by coupling conductive carbon black (VXC-72R) with ferricyanide probe. The VXC-72R was decorated with nonionic surfactant Tween to enhance the sensitivity and coated on glassy carbon electrode (GCE), whereas K[Fe(CN)] was introduced into electrolyte solution as an internal reference probe to realize dual-signal outputs. The present ratiometric electrochemical sensor achieved a highly sensitive and selective detection of BPA in PBS solution (pH = 7.0), with a linear range of 0.08-40.0 μM and detection limit of 0.05 μM. Moreover, it has been successfully applied to the determination of BPA in real lake water and milk samples with the satisfactory recoveries rates of 94.8-102.3 %.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2024.127084DOI Listing

Publication Analysis

Top Keywords

ratiometric electrochemical
12
electrochemical sensor
12
sensor bisphenol
8
conductive carbon
8
carbon black
8
ferricyanide probe
8
construction ratiometric
4
detection
4
bisphenol detection
4
detection coupling
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!