Introduction: Optimizing vascular access for hemodialysis in end-stage kidney disease is crucial. While arteriovenous fistulas (AVFs) are preferred for better patency and fewer complications, many patients require alternatives options like arteriovenous grafts (AVGs) due to anatomical constraints. This study compares outcomes between elbow and upper arm (UA) basilic veins for forearm loop AVGs, highlighting the potential benefits of the UA basilic vein to improve patency and feasibility in patients with poor elbow veins through retrospective analysis.

Methods: This retrospective study analyzed 59 limbs of patients who underwent forearm loop AVG formation from January 2018 to June 2022. Elbow veins (basilic, median cubital, brachial) and UA basilic veins were evaluated for suitability using duplex ultrasonography. AVG decisions were based on patient age, health, and vein diameter (⩾2.3 mm). Statistical analyses compared baseline characteristics and evaluated primary and secondary patency rates at 12 and 18 months using Pearson's chi-square, Student's -test, Kaplan-Meier survival analysis, and the Log-rank test.

Results: Thirty-six patients had elbow anastomosis, while 23 had UA anastomosis for forearm loop AVG. The elbow group had a higher male proportion (72.7% vs 34.7% in UA,  = 0.005) and larger elbow vein diameters (2.52 ± 0.19 mm vs 2.16 ± 0.21 mm in UA,  < 0.001). Primary patency rates at 12 months were 72.7% for elbow and 56.2% for UA; at 18 months, 59.4% and 25.5%, respectively ( = 0.376). Secondary patency rates at 12 months were 75.7% for elbow and 62.2% for UA; at 18 months, 67.8% and 33.9%, respectively ( = 0.238).

Conclusion: The primary and secondary patency rates of forearm loop AVG with UA basilic vein anastomosis were not inferior to those with elbow veins anastomosis. UA basilic vein can be a feasible alternative for creating forearm loop AVG when elbow veins are not suitable.

Download full-text PDF

Source
http://dx.doi.org/10.1177/11297298241291695DOI Listing

Publication Analysis

Top Keywords

forearm loop
16
elbow veins
12
basilic veins
12
anastomosis forearm
8
arteriovenous grafts
8
upper arm
8
arm basilic
8
end-stage kidney
8
kidney disease
8
loop avg
8

Similar Publications

Aim: The purpose of this study is to present the ultrasound appearance of a previously undescribed-at-imaging variant of the ulnar nerve near the Guyon's canal.

Material And Methods: The ultrasound database of one of the authors, who has more than 10 years of experience in peripheral nerve ultrasound, was searched for the phrases "UN variant" or "UN loop." The other two authors, with more than 10 years of experience in nerve imaging, retrospectively reviewed the static sonograms as well as the videoclips stored, to confirm the findings.

View Article and Find Full Text PDF

Introduction: Optimizing vascular access for hemodialysis in end-stage kidney disease is crucial. While arteriovenous fistulas (AVFs) are preferred for better patency and fewer complications, many patients require alternatives options like arteriovenous grafts (AVGs) due to anatomical constraints. This study compares outcomes between elbow and upper arm (UA) basilic veins for forearm loop AVGs, highlighting the potential benefits of the UA basilic vein to improve patency and feasibility in patients with poor elbow veins through retrospective analysis.

View Article and Find Full Text PDF

Gesture Recognition Framework for Teleoperation of Infrared (IR) Consumer Devices Using a Novel pFMG Soft Armband.

Sensors (Basel)

September 2024

Applied Mechatronics and Biomedical Engineering Research (AMBER) Group, School of Mechanical, Materials, Mechatronic and Biomedical Engineering, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW 2522, Australia.

Wearable technologies represent a significant advancement in facilitating communication between humans and machines. Powered by artificial intelligence (AI), human gestures detected by wearable sensors can provide people with seamless interaction with physical, digital, and mixed environments. In this paper, the foundations of a gesture-recognition framework for the teleoperation of infrared consumer electronics are established.

View Article and Find Full Text PDF

An unreported variant of palmaris longus muscle.

Anat Cell Biol

December 2024

Department of Mathematics, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India.

Palmaris longus is a highly variable muscle of the forearm. Knowledge of its variability is of importance to plastic surgeons, hand surgeons and radiologists. During our routine dissection classes for undergraduate medical students, a peculiar palmaris longus muscle was noted in the left upper limb of an adult male cadaver.

View Article and Find Full Text PDF

The ability of a novel biorealistic hand prosthesis for grasp force control reveals improved neural compatibility between the human-prosthetic interaction. The primary purpose here was to validate a virtual training platform for amputee subjects and evaluate the respective roles of visual and tactile information in fundamental force control tasks. We developed a digital twin of tendon-driven prosthetic hand in the MuJoCo environment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!