Aim We aim to assess the long-term revision rates in patients with adult spinal deformity (ASD) undergoing posterior instrumentation with or without supplemental anterior lumbar interbody fusion (ALIF) with a median of eight years of follow-up. Materials and methods Based on a previous pilot randomized controlled trial (RCT) from 2012, all previous participants were invited to a clinical and radiographic follow-up. Full medical records from the total cohort were reviewed from the time of operation to the follow-up, and information on revision surgery due to mechanical failure was obtained and compared between the groups. Results Of the original 17 patients included in the RCT, 15 were available for follow-up and 10 attended the clinical and radiographic examination. A retrospective review was performed of the entire original cohort. The median age at follow-up was 67 (61-71) years, and the median follow-up time was 7.7 (5.1-8.8) years. Revision rates among ALIF patients were three out of seven (43%) and eight out of 10 (80%) among non-ALIF patients with pseudoarthrosis and rod breakage being the main cause. Time to failure was longer in ALIF patients with a median of 47 (28-53) months compared with non-ALIF patients with a median of 26 (9-31) months. Conclusion This study revealed a lower rate of revision surgery and a longer time to failure in patients undergoing ASD surgery with supplemental ALIF compared with posterior instrumentation alone. Further studies with a larger sample size are needed to make conclusions on the effect of a supplemental ALIF to posterior instrumentation on lowering the risk of mechanical failure in patients with adult spinal deformity.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11498895 | PMC |
http://dx.doi.org/10.7759/cureus.70020 | DOI Listing |
Arch Orthop Trauma Surg
January 2025
Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.
Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.
View Article and Find Full Text PDFEur Spine J
January 2025
Texas Back Institute Research Foundation, Plano, TX, USA.
Purpose: The purpose of this study was to investigate the outcomes of minimally invasive PCF using an interfacet joint fusion cage.
Methods: The inclusion criteria consisted of patients who underwent a PCF using an interfacet device (Cavux, Providence Medical Technology Inc.) at a single institution and were at least 6 months postoperative.
Aim: We investigated the short- term results of dynamic/semi-rigid stabilization in patients with cervi-cal spinal stenosis and compare them with patients for which decompression and posterior cer-vical fusion was performed.
Material And Methods: 28 patients were included in this study. Group 1 was the semi-rigid group (four male, ten fe-male), group 2 was the fusion group (nine male, five female).
Retina
February 2025
Department of Ophthalmology, Liyang Hospital of Chinese Medicine, Liyang, China.
Purpose: To describe a custom bent 27-gauge needle-guided suture snare technique for scleral fixation of posterior chamber intraocular lenses (PCIOL).
Methods: An 8-0 polypropylene suture was threaded into the lumen of a custom bent 27-gauge needle, and the needle tip was advanced into the eye from the intraocular lens (IOL) fixation point. The suture was threaded through the posterior limbal incision inside the IOL haptic loop and pulled out.
J Orthop Surg Res
January 2025
Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg- Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
Background: In atlantoaxial instabilities, posterior C1/C2 fusion using lateral mass screws (LMS) or pedicle screws (PS) in a mono- or bicortical position in the atlas is a typical treatment. The bone microstructure and positioning of the screw trajectories appear to be of significant relevance for stability.
Purpose: The aim of this study was a comparative analysis of the mechanical durability of screw fixation concerning microstructural characteristics of the trajectories of LMS and PS in mono- and bicortical position.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!