A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical investigation of positive reduction in the femoral neck fracture: a finite element analysis. | LitMetric

Biomechanical investigation of positive reduction in the femoral neck fracture: a finite element analysis.

Front Bioeng Biotechnol

Department of Trauma Surgery, Orthopedics and Plastic Surgery, University Medical Center Göttingen, Göttingen, Germany.

Published: October 2024

Background: Gotfried positive reduction offers an alternative strategy for femoral neck fracture (FNF) when achieving anatomical reduction is challenging. However, the biomechanical consequences of positive reduction remain unclear. The purpose of this study was to investigate the biomechanical behavior of positive reduction across different Pauwels classification, providing a reference for quantifying positive reduction in clinical practice.

Methods: Three-dimensional (3D) models of FNF were established and categorized according to the Pauwels classifications (Pauwels I, II, and III), each of them contained seven models with different reduction qualities, including an anatomical reduction model, two negative reduction models, and four positive reduction models, all of which were stabilized with dynamic hip screws (DHS) and cannulated screws (CS). We investigated the maximal von-Mises stress of internal fixation and proximal femoral, femoral fragment displacement, and maximal von-Mises strain at the proximal fragment fracture site when a 2100 N load was applied to the femoral head.

Results: The maximum von-Mises stress on the internal fixators in each Pauwels group was lowest in the anatomical reduction model. In the Pauwels I group, positive reduction exceeding 3 mm resulted in the maximum von-Mises stress on the internal fixators surpassing that of the negative reduction model. For the Pauwels II group, positive reduction beyond 2 mm led to the maximum von-Mises stress on the internal fixators exceeding that of the negative reduction model. In the Pauwels III group, positive reduction beyond 1 mm caused the maximum von-Mises stress on the internal fixators to be higher than that of the negative reduction model. The maximum von-Mises strain at the fracture site of proximal femur fragment increased with positive reduction. Varus displacement increased in positive reduction models as the Pauwels angle rose, potentially exacerbating rotation deformity in Pauwels III group.

Conclusion: Excessive positive reduction may increase the risk of FNF failure after internal fixation. From a biomechanical stability perspective, positive reduction should be limited to 3 mm or below in the Pauwels I group, restricted to not exceed 2 mm in the Pauwels II group, and should not exceed 1 mm in the Pauwels III group. Negative reduction should be avoided in all Pauwels groups.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11496117PMC
http://dx.doi.org/10.3389/fbioe.2024.1374299DOI Listing

Publication Analysis

Top Keywords

positive reduction
52
reduction
22
reduction model
20
negative reduction
20
von-mises stress
20
stress internal
20
maximum von-mises
20
pauwels group
20
pauwels iii
16
internal fixators
16

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!