Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Common-mode currents can degrade the RF coil performance and introduce potential safety hazards in MRI. Baluns are the standard method to suppress these undesired common-mode currents. Specifically, floating baluns are preferred in many applications because they are removable, allow post-installation adjustment and avoid direct soldering on the cable. However, floating baluns are typically bulky to achieve excellent common-mode suppression, taking up valuable space in the MRI bore. This is particularly severe for multi-nuclear MRI/MRS applications, as two RF systems exist. In this work, we present a novel dual-tuned floating balun that is fully removable, does not require any physical connection to the coaxial cable, and has a significantly reduced footprint. The floating design employs an inductive coupling between the cable solenoid and a floating solenoid resonator rather than a direct physical connection. Unlike the previous floating solenoid balun, this balun employs a two-layer design further to improve the mutual coupling between the two solenoids. A pole-insertion method is used to suppress common-mode currents at two user-selectable frequencies simultaneously. Bench testing of the fabricated device at 7 T demonstrated high common-mode rejection ratios at Larmor frequencies of both H and Na, even with a compact dimension (diameter 18 mm and length 12 mm). This balun's removable, compact, and multi-resonant nature enables light-weighting, allows more coil elements, and improves cable management for advanced multi-nuclear MRI/MRS systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.mri.2024.110268 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!