Multidimensional coherent spectroscopy is a powerful tool for understanding the ultrafast dynamics of complex quantum systems. To fully characterize the nonlinear optical response of a system, multiple pulse sequences must be recorded and quantitatively compared. We present a new single-scan method that enables rapid and parallel acquisition of all unique pulse sequences corresponding to first- and third-order degenerate wave-mixing processes. Signals are recorded with shot-noise limited detection, enabling acquisition times of ~2 minutes with ~100 zs phase stability and ~8 orders of dynamic range, in a collinear geometry, on a single-pixel detector. We demonstrate this method using quantum well excitons, and quantitative analysis reveals new insights into the bosonic nature of excitons. This scheme may enable rapid and scalable analysis of unique chemical signatures, metrology of optical susceptibilities, nonperturbative coherent control, and the implementation of quantum information protocols using multidimensional spectroscopy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11494713 | PMC |
http://dx.doi.org/10.1364/optica.6.000735 | DOI Listing |
ChemSusChem
January 2025
University of Rochester, Department of Chemical Engineering, ., 14627, Rochester, UNITED STATES OF AMERICA.
Per- and polyfluoroalkyl substances (PFAS) are extremely stable chemicals that are essential for modern life and decarbonization technologies. Yet PFAS are persistent pollutants that are harmful to human health. Hexafluoropropylene oxide dimer acid (GenX), a replacement for the PFAS chemical perfluorooctanoic acid, continues to pollute waterways.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
Department of Physics and Astronomy and Center for Fundamental Physics, Northwestern University, Evanston, Illinois 60208, USA.
We introduce a novel technique for enhancing the robustness of light-pulse atom interferometers against the pulse infidelities that typically limit their sensitivities. The technique uses quantum optimal control to favorably harness the multipath interference of the stray trajectories produced by imperfect atom-optics operations. We apply this method to a resonant atom interferometer and achieve thousandfold phase amplification, representing a 50-fold improvement over the performance observed without optimized control.
View Article and Find Full Text PDFClin Chem
January 2025
Department of Internal Medicine and Pediatrics, HIV Cure Research Center, Ghent University Hospital, Ghent University Ghent, Belgium.
Background: Persistent latent reservoirs of intact HIV-1 proviruses, capable of rebounding despite suppressive antiretroviral therapy (ART), hinder efforts towards an HIV-1 cure. Hence, assays specifically quantifying intact proviruses are crucial to assess the impact of curative interventions. Two recent assays have been utilized in clinical trials: intact proviral DNA assay (IPDA) and quadruplex quantitative PCR (Q4PCR).
View Article and Find Full Text PDFJ Clin Sleep Med
January 2025
Natural Interaction Lab, Thom Building, Department of Engineering, University of Oxford, Oxford, United Kingdom.
Study Objectives: Home sleep apnea testing based on peripheral arterial tonometry (P-HSAT) is increasingly being deployed because of its ability to test for multiple nights. However, P-HSATs do not have access to modalities such as airflow and cortical arousals and instead rely on alternative sources of information to detect respiratory events. This results in an a-priori performance disadvantage.
View Article and Find Full Text PDFSci Rep
January 2025
Postdoctoral Innovation Practice Base, Chengdu Textile College, Chengdu, 611731, China.
In radar systems, element gain-phase errors can degrade the performance of space-time adaptive processing (STAP), and even cause complete failure. To address this issue, the STAP with the coprime sampling structure based on optimal singular value thresholding is proposed. The algorithm corrects errors by adding four calibrated auxiliary elements and auxiliary pulses to the original array and pulse sequence, while maintaining the coprime sampling structure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!