Background: The choice of angiography system could influence the outcomes of mechanical thrombectomy (MT) in the treatment of acute ischemic stroke (AIS), but its impact is not yet well understood. This study aims to compare the clinical and technical outcomes of MT performed with single plane versus biplane angiography systems.

Method: We conducted a systematic review and meta-analysis, following PRISMA guidelines, by searching PubMed, Embase, Web of Science, and Scopus to include studies on patients with AIS who underwent MT with either single plane or biplane angiography up to May 4, 2024. The primary outcome was a favorable outcome defined as a modified Rankin Scale (mRS) score of 0-2 at 90 days after the procedure. Data were analyzed using a random-effects model and heterogeneity was assessed using the I test and Q statistics.

Results: Five studies with a total of 1562 patients were analyzed. Of these, 68.4% were treated with biplane systems and 31.6% with single plane systems. Single plane angiography was associated with a significantly higher rate of favorable outcomes (OR 1.43; 95% CI 1.13 to 1.80; P<0.01). There were no significant differences in successful recanalization, periprocedural complications, procedure time, total fluoroscopy time, or contrast volume between the two systems.

Conclusion: While single plane angiography systems may offer slightly better outcomes in MT for AIS, both systems appear equally effective in most clinical and technical perspectives, suggesting that system selection may be more dependent on availability and procedural requirements rather than inherent superiority. Our findings may encourage clinicians to use single-plane angiography in settings where the biplane angiography suite availability is limited, but it should be noted that this observation may have been influenced by selection bias, particularly since the larger studies included in our meta-analysis did not observe this effect in adjusted analyses for potential confounder factors.

Download full-text PDF

Source
http://dx.doi.org/10.1136/jnis-2024-022381DOI Listing

Publication Analysis

Top Keywords

single plane
20
biplane angiography
12
plane biplane
8
mechanical thrombectomy
8
acute ischemic
8
ischemic stroke
8
systematic review
8
review meta-analysis
8
single
5
plane
5

Similar Publications

Background: Appendicectomy is a common procedure in children. Regional anaesthesia helps reduce requirements for opioids and hospital stay and enhances recovery. Laparoscopic-assisted Transversus Abdominus Plane block (L-TAP) was shown to be efficient and potentially superior to port site infiltration (PSI); however, this was not previously studied in paediatric appendicitis.

View Article and Find Full Text PDF

Atomic defects in solids offer a versatile basis to study and realize quantum phenomena and information science in various integrated systems. All-electrical pumping of single defects to create quantum light emission has been realized in several platforms including color centers in diamond and silicon carbide, which could lead to the circuit network of electrically triggered single-photon sources. However, a wide conduction channel which reduces the carrier injection per defect site has been a major obstacle.

View Article and Find Full Text PDF

Full Quantum Dynamics Study for H Atom Scattering from Graphen.

J Phys Chem A

January 2025

Université Paris-Saclay, CNRS, Institut des Sciences Moléculaires d'Orsay UMR 8214, 91405 Orsay, France.

This study deals with the understanding of hydrogen atom scattering from graphene, a process critical for exploring C-H bond formation and energy transfer during atom surface collision. In our previous work [Shi, L.; 2023, 159, 194102], starting from a cell with 24 carbon atoms treated periodically, we have achieved quantum dynamics (QD) simulations with a reduced-dimensional model (15D) and a simulation in full dimensionality (75D).

View Article and Find Full Text PDF

Discovering electrocatalysts that can efficiently convert carbon dioxide (CO) to valuable fuels and feedstocks using excess renewable electricity is an emergent carbon-neutral technology. A single metal atom embedded in doped graphene, , single-atom catalyst (SAC), possesses high activity and selectivity for electrochemical CO reduction (COR) to CO, yet further reduction to hydrocarbons is challenging. Here, using density functional theory calculations, we investigate stability and reactivity of a broad SAC chemical space with various metal centers (3d transition metals) and dopants (2p dopants of B, N, O; 3p dopants of P, S) as electrocatalysts for COR to methane and methanol.

View Article and Find Full Text PDF

Background: Advancements in cardiac catheterization have improved survival for pediatric congenital heart disease patients, but the associated ionizing radiation risks necessitate ethical consideration.

Methods: This study presents an empirical model, developed from 3131 unique pediatric procedures, to establish alert levels based on a patient's lateral thickness of the thorax for various procedural categories during diagnostic or interventional cardiac catheterization. The model uses linear regression of logarithmic reference air kinetic energy released per unit mass (KERMA) and air KERMA area product, also referred to as dose area product, to set alert levels at the top 95% and 99% of patient data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!