Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 144
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The patency of intracranial stents may not be reliably assessed with either CT angiography or MR angiography due to imaging artifacts. We investigated the potential of ultra-high resolution CT angiography using a photon counting detector (PCD) CT to address this limitation by optimizing scanning and reconstruction parameters.
Methods: A phantom with different flow diverters was used to optimize PCD-CT reconstruction parameters, followed by imaging of 14 patients with intracranial stents using PCD-CT. Images were reconstructed using three kernels based on the phantom results (Hv56, Hv64, and Hv72; Hv=head vascular) and one kernel to virtually match the resolution of standard CT angiography (Hv40). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements were calculated. Subjective image quality and diagnostic confidence (DC) were assessed using a five point visual grading scale (5=best, 1=worst) and a three point grading scale (1=best, 3=worst), respectively, by two independent neuroradiologists.
Results: Phantom images demonstrated the highest image quality across dose levels for 0.2 mm reconstructions with Hv56 (4.5), Hv64 (5), and Hv72 (5). In patient images, SNR and CNR decreased significantly with increasing kernel sharpness compared with control parameters. All reconstructions showed significantly higher image quality and DC compared with the control reconstruction with Hv40 kernel (P<0.001), with both image quality and DC being highest with Hv64 (0.2 mm) and Hv72 (0.2 mm) reconstructions.
Conclusion: Ultra-high resolution PDC-CT angiography provides excellent visualization of intracranial stents, with optimal reconstructions using the Hv64 and the Hv72 kernels at 0.2 mm.