A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultra-high resolution CT angiography for the assessment of intracranial stents and flow diverters using photon counting detector CT. | LitMetric

Background: The patency of intracranial stents may not be reliably assessed with either CT angiography or MR angiography due to imaging artifacts. We investigated the potential of ultra-high resolution CT angiography using a photon counting detector (PCD) CT to address this limitation by optimizing scanning and reconstruction parameters.

Methods: A phantom with different flow diverters was used to optimize PCD-CT reconstruction parameters, followed by imaging of 14 patients with intracranial stents using PCD-CT. Images were reconstructed using three kernels based on the phantom results (Hv56, Hv64, and Hv72; Hv=head vascular) and one kernel to virtually match the resolution of standard CT angiography (Hv40). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements were calculated. Subjective image quality and diagnostic confidence (DC) were assessed using a five point visual grading scale (5=best, 1=worst) and a three point grading scale (1=best, 3=worst), respectively, by two independent neuroradiologists.

Results: Phantom images demonstrated the highest image quality across dose levels for 0.2 mm reconstructions with Hv56 (4.5), Hv64 (5), and Hv72 (5). In patient images, SNR and CNR decreased significantly with increasing kernel sharpness compared with control parameters. All reconstructions showed significantly higher image quality and DC compared with the control reconstruction with Hv40 kernel (P<0.001), with both image quality and DC being highest with Hv64 (0.2 mm) and Hv72 (0.2 mm) reconstructions.

Conclusion: Ultra-high resolution PDC-CT angiography provides excellent visualization of intracranial stents, with optimal reconstructions using the Hv64 and the Hv72 kernels at 0.2 mm.

Registration: BASEC 2021-00343.

Download full-text PDF

Source
http://dx.doi.org/10.1136/jnis-2024-022041DOI Listing

Publication Analysis

Top Keywords

intracranial stents
12
image quality
12
ultra-high resolution
8
resolution angiography
8
flow diverters
8
photon counting
8
counting detector
8
hv56 hv64
8
hv64 hv72
8
grading scale
8