Impact of PM filter extraction solvent on oxidative potential and chemical analysis.

J Air Waste Manag Assoc

Department of BioMolecular Sciences, University of Mississippi, University, MS, USA.

Published: January 2025

Fine particulate matter (PM) is hypothesized to induce oxidative stress, and has been linked to acute and chronic adverse health effects. To better understand the risks and underlying mechanisms following exposure, PM is collected onto filters but prior to toxicological analysis, particles must be removed from filters. There is no standard method for filter extraction, which creates the possibility that the methods of extraction selected can alter the chemical composition and ultimately the biological implications. In this study, comparisons were made between extraction solvents (methanol (MeOH), dichloromethane (DCM), 0.9% saline, and Milli-Q water) and the results of oxidative potential and elemental concentration analysis of PM collected across sites in Arkansas, USA. Significant differences were observed between solvents, with DCM having significantly different results compared to all other extraction solvents ( ≤ 0.001). Significant correlations between element, black carbon, and PM concentrations and oxidative potential were observed. The observed correlations were extraction solvent dependent. For example, in saline extracted samples, oxidative potential had significant negative correlations with: Ba, Cd, Ce, Co, Ga, Mn and significant positive correlations with: Cr, Ni, Th, U. While in MeOH extracted samples, significant positive correlations were only between oxidative potential and Ga, U and significant negative correlations with V. This indicates that PM samples extracted with different solvents will yield different conclusions about the causal components. This study highlights the importance of filter extraction methods in interpretation of oxidative potential results and comparisons between studies. While there is no standard method for PM filter extraction, variation of extraction methods impact analytical results. This project identifies that extraction method variation, particularly extraction solvent selection, leads to discrepancies in chemical and toxicological analysis for PM collected on the same filter. This work highlights the need for methods standardization to support accurate comparisons between PM research studies, thus providing better understanding of PM across the globe.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10962247.2024.2417736DOI Listing

Publication Analysis

Top Keywords

oxidative potential
24
filter extraction
16
extraction solvent
12
extraction
11
toxicological analysis
8
standard method
8
method filter
8
extraction solvents
8
analysis collected
8
extracted samples
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!