AI Article Synopsis

  • Researchers developed a new type of magnetic nanoparticles, C18@PS-DVB-GMA-Fe3O4, to help remove blood phospholipids, useful for analyzing substances in human plasma.
  • These nanoparticles were utilized in a Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method to streamline the extraction and cleaning process before assessing propofol levels using supercritical fluid chromatography (SFC).
  • The SFC analysis showed a strong linear relationship for propofol concentrations, with high recovery rates and low variability, indicating that this method is efficient and accurate for measuring propofol in plasma samples.

Article Abstract

Novel C18-functionalized magnetic nanomaterials; i.e., C18@poly-styrene-divinylbenzene-glycidyl methacrylate-Fe3O4 (C18@PS-DVB-GMA-Fe3O4) have been synthesized by using N, N-dimethyloctadecylamine as modifying agent, which could be beneficial to remove the blood phospholipids. The C18@PS-DVB-GMA-Fe3O4 nanoparticles have been used and evaluated in the Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) procedure for human plasma prior to the analysis of propofol by supercritical fluid chromatography (SFC). In the QuEChERS procedure, human plasma samples are directly mixed with extraction solvent and C18@PS-DVB-GMA-Fe3O4 nanoparticles, and the extraction and cleanup procedures have been accomplished simultaneously. The SFC separation was performed with a C18 column (Thermo Scientific™ Acclaim™ 120, 250 × 4. 6 mm, 5 μm) within 5 min, using thymol as the internal standard. Supercritical carbon dioxide was used as the mobile phase with methanol as the cosolvent at the flow rate of 1.0 mL/min. The column temperature was 38°C, and detection wavelength was 275 nm. A good linearity was obtained among the propofol concentration range of 0.5-10 mg/L (R2 = 0.9997) with the limit of detection of 0.17 mg/L. Recoveries were in the range of 76.5-91.9%, with RSD less than 7.9%. These results suggested that method is convenient, rapid with high accuracy and little matrix effect, and suitable for rapid determination of propofol plasma concentration.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmae053DOI Listing

Publication Analysis

Top Keywords

human plasma
12
determination propofol
8
c18-functionalized magnetic
8
magnetic nanomaterials
8
supercritical fluid
8
fluid chromatography
8
c18@ps-dvb-gma-fe3o4 nanoparticles
8
quechers procedure
8
procedure human
8
fast determination
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!