A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparison study of 589 and 650 nm on improving stored whole blood stability by irradiation with a low-power diode pumping solid-state laser. | LitMetric

Objective: To assess the effects of diode-pumped solid-state laser irradiation with 589nm and 650nm wavelengths on the stability of stored red blood cells in vitro.

Methods: This is an intervention study that was conducted from April to July 2021 at the Physiology and Medical Physics Laboratory, College of Medicine, Mustansiriyah University, Baghdad, Iraq, and comprised samples of healthy, adult human blood that were put in tubes with citrate-phosphate dextrose-adenine as an anticoagulant. The blood sample was divided into eight equal aliquots and stored for 21 days at 4ºC. The stability test was done on days 0, 7, 14 and 21 of storage time for non-irradiated and radiated aliquots. For 15 minutes, the irradiated aliquots were subjected to a diode-pumped solid-state laser with a wavelength of 589nm or a laser with a wavelength of 650nm at frequencies of 30, 50 and 70 J/cm². Data was analysed using SPSS 24.

Results: Exposure of the whole blood to 589nm and a radiation dose of 70J/cm², 50J/cm² and 30J/cm² was associated with a significant reduction in the percentage of haemolysis that ranged 23-42% throughout the whole storage time. Exposure of the whole blood to 650nm wavelength low-level laser therapy and a radiation dose of 70J/cm², 50J/cm² and 30J/cm² was associated with much less reduction in the percentage of haemolysis that ranged 5-9% throughout the whole storage time.

Conclusions: Both 589nm and to some extent 650nm low-level laser irradiation generally reduced haemolysis. The wavelength of 589nm lasers had a more effective influence than the 650nm counterpart in improving the stored red blood cells.

Download full-text PDF

Source
http://dx.doi.org/10.47391/JPMA-BAGH-16-38DOI Listing

Publication Analysis

Top Keywords

solid-state laser
12
improving stored
8
diode-pumped solid-state
8
laser irradiation
8
stored red
8
red blood
8
blood cells
8
storage time
8
laser wavelength
8
wavelength 589nm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!