X-ray multi-projection imaging (XMPI) is an emerging experimental technique for the acquisition of rotation-free, time-resolved, volumetric information on stochastic processes. The technique is developed for high-brilliance light-source facilities, aiming to address known limitations of state-of-the-art imaging methods in the acquisition of 4D sample information, linked to their need for sample rotation. XMPI relies on a beam-splitting scheme, that illuminates a sample from multiple, angularly spaced viewpoints, and employs fast, indirect, X-ray imaging detectors for the collection of the data. This approach enables studies of previously inaccessible phenomena of industrial and societal relevance such as fractures in solids, propagation of shock waves, laser-based 3D printing, or even fast processes in the biological domain. In this work, we discuss in detail the beam-splitting scheme of XMPI. More specifically, we explore the relevant properties of X-ray splitter optics for their use in XMPI schemes, both at synchrotron insertion devices and XFEL facilities. Furthermore, we describe two distinct XMPI schemes, designed to faciliate large samples and complex sample environments. Finally, we present experimental proof of the feasibility of MHz-rate XMPI at the European XFEL. This detailed overview aims to state the challenges and the potential of XMPI and act as a stepping stone for future development of the technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11542665PMC
http://dx.doi.org/10.1107/S1600577524008488DOI Listing

Publication Analysis

Top Keywords

x-ray multi-projection
8
multi-projection imaging
8
beam-splitting scheme
8
xmpi schemes
8
xmpi
7
development crystal
4
crystal optics
4
x-ray
4
optics x-ray
4
imaging
4

Similar Publications

X-ray spectromicroscopy is extensively utilized for nondestructive mapping of chemical states in materials. However, understanding and analyzing the geometric and topological aspects of such data pose challenges due to their representation in 4D space, encompassing (x, y, z) coordinates along with the energy (E) axis and often extending to 5D space with the inclusion of time (t) or reaction degree. In this study, we addressed this challenge by developing a new approach and introducing a device named `4D-XASView', specifically designed for visualizing X-ray absorption fine structures (XAFS) data in 4D (comprising 3D space and energy), through a multi-projection system, within the virtual reality (VR) environment.

View Article and Find Full Text PDF

X-ray multi-projection imaging (XMPI) is an emerging experimental technique for the acquisition of rotation-free, time-resolved, volumetric information on stochastic processes. The technique is developed for high-brilliance light-source facilities, aiming to address known limitations of state-of-the-art imaging methods in the acquisition of 4D sample information, linked to their need for sample rotation. XMPI relies on a beam-splitting scheme, that illuminates a sample from multiple, angularly spaced viewpoints, and employs fast, indirect, X-ray imaging detectors for the collection of the data.

View Article and Find Full Text PDF

Detection and characterization of hidden defects, impurities, and damages in homogeneous materials like aluminum die casting materials, as well as composite materials like Fiber-Metal Laminates (FML), is still a challenge. This work discusses methods and challenges in data-driven modeling of automated damage and defect detectors using measured X-ray single- and multi-projection images. Three main issues are identified: Data and feature variance, data feature labeling (for supervised machine learning), and the missing ground truth.

View Article and Find Full Text PDF

X-ray multi-projection imaging (XMPI) has the potential to provide rotation-free 3D movies of optically opaque samples. The absence of rotation enables superior imaging speed and preserves fragile sample dynamics by avoiding the centrifugal forces introduced by conventional rotary tomography. Here, we present our XMPI observations at the ID19 beamline (ESRF, France) of 3D dynamics in melted aluminum with 1000 frames per second and 8 µm resolution per projection using the full dynamical range of our detectors.

View Article and Find Full Text PDF

Iterative optimization of relative stopping power by single detector based multi-projection proton radiography.

Phys Med Biol

March 2019

Department of Radiation Oncology, Emory School of Medicine, Atlanta, GA, United States of America. Author to whom any correspondence should be addressed.

In proton therapy, range uncertainties induced by the conversion from x-ray CT (xCT) Hounsfield units (HU) to relative stopping power (RSP) compromise the precision of dose delivery. To reduce range uncertainties induced by HU-converted RSPs, this study investigates optimizing the RSP of individual voxels in xCT iteratively based on multi-projection proton radiography (pRG) acquired using a single amorphous silicon flat panel imager. Time-resolved dose rate functions (DRF) were measured by the imager placed downstream of a test phantom consisting of tissue substitute materials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!