A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultra high-performance liquid chromatography tandem mass spectrometry: Development and validation of an analytical method for N2-Ethyl-2'-deoxyguanosine in dried blood spot. | LitMetric

In the body, ethanol is metabolized to acetaldehyde by alcohol dehydrogenase and CYP2E1. Acetaldehyde is the main carcinogen that forms DNA adducts, N2-Ethylidene-2'-deoxyguanosine (N2-Ethylidene-dG), which can cause DNA damage and lead to cancer. However, N2-Ethylidene-dG is an unstable form at the nucleoside level and is difficult to measure. So it needs to be reduced using NaBH to become N2-Ethyl-2'-deoxyguanosine (N2-Et-dG). This study aims to obtain a selective, sensitive, and validated analytical method to determine N2-Et-dG using ultra-high-performance liquid chromatography-tandem mass spectrometry with allopurinol as the internal standard. The N2-Et-dG analysis was performed using a C Acquity® Bridged Ethylene Hybrid column of (1.7 μm, 100 mm × 2.1 mm). The sample matrix used was dried blood spots, and then the DNA sample was extracted using the QIAamp DNA Mini Kit. The optimum analysis conditions were obtained in a combination eluent of 0.1 % acetic acid and methanol (60:40 v/v) with a flow rate of 0.1 mL/min and eluted isocratically for 5 min. Quantification analysis was performed using triple quadrupole mass spectrometry with electrospray ionization in positive mode, with detection at / 296.16 > 180.16 for N2-Et-dG and 137.03 > 110.05 for allopurinol, respectively. The validated analytical method follows the 2018 USA Food and Drug Administration guidelines with a linear concentration range of 5-200 ng/mL.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11489359PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e38610DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
12
analytical method
12
dried blood
8
validated analytical
8
analysis performed
8
ultra high-performance
4
high-performance liquid
4
liquid chromatography
4
chromatography tandem
4
tandem mass
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!