AI Article Synopsis

  • The study aimed to investigate the effectiveness of CT quantitative parameters in distinguishing between lipid-poor adenoma (LPA) and nodular hyperplasia in adrenal lesions.
  • Researchers analyzed 128 patients, measuring various CT parameters, including attenuation values and lesion volume, and developed a logistic regression model to evaluate diagnostic accuracy.
  • The model showed a good performance with an area under the ROC curve (AUC) of 0.835, with better sensitivity and specificity than radiologists' assessments, indicating that CT metrics can be more reliable for diagnosis.

Article Abstract

Objectives: To explore the potential of CT quantitative parameters in differentiating adrenal lipid-poor adenoma (LPA) from nodular hyperplasia and evaluate diagnostic performance.

Materials And Methods: Patients with LPA or nodular hyperplasia who underwent contrast-enhanced CT before adrenalectomy were analyzed retrospectively. The study included 128 patients (83 with LPA and 45 with nodular hyperplasia). Each lesion's unenhanced attenuation, portal-venous phase attenuation (CTp), and the portal-venous phase attenuation of the abdominal aorta were evaluated. We subsequently calculated absolute enhancement [a lesion's portal-venous phase attenuation minus unenhanced attenuation (in HUs)], relative enhancement (absolute enhancement divided by unenhanced attenuation), and the relative enhancement ratio [(absolute enhancement divided by abdominal aorta's portal-venous phase attenuation) ×100%]. Lesion number and size were recorded. Volume was assessed by ITK-snap software and the ratio of lesion volume to ipsilateral adrenal volume (volume ratio) was determined. Intergroup differences were analyzed using Student's t-test and chi-squared test. Logistic regression models were developed, and receiver operating characteristic (ROC) curves were constructed to determine the area under the ROC curve (AUC), sensitivity, and specificity. The model's performance was then compared against radiologists' subjective assessments, and the inter- and intra-reader agreement values among radiologists were calculated.

Results: Portal-venous phase attenuation, volume ratio, and lesion number were independent predictors of LPA. The logistic regression model incorporating CTp, volume ratio, and lesion number achieved an AUC of 0.835, with a sensitivity of 73.5% and a specificity of 80.0%. The radiologists' diagnostic specificity and accuracy appeared to be inferior to the model. The inter-reader agreement among radiologists ranged from 0.082 to 0.535, and the intra-reader agreement of two radiologists were 0.734 and 0.583.

Conclusion: The portal-venous phase CT demonstrated potential in distinguishing LPA from nodular hyperplasia. The diagnostic performance of the model integrating CTp, volume ratio, and lesion number outperformed radiologists in terms of variability and reproducibility.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00261-024-04642-9DOI Listing

Publication Analysis

Top Keywords

portal-venous phase
24
nodular hyperplasia
20
phase attenuation
20
lpa nodular
16
lesion number
16
ratio lesion
16
volume ratio
16
unenhanced attenuation
12
adrenal lipid-poor
8
lipid-poor adenoma
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!