A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rates and predictors of loss to follow-up for sporadic vestibular schwannomas undergoing imaging surveillance. | LitMetric

AI Article Synopsis

  • This study investigates the effectiveness of a "wait-and-scan" approach using MRI for managing patients with small to medium-sized vestibular schwannomas (VS), aiming to assess patient adherence to follow-up.
  • Over six years, 270 patients were tracked, revealing that 27% were completely lost to follow-up before receiving treatment, while another 22% missed scheduled MRI follow-ups.
  • The research identified key factors for loss to follow-up, including living out of state and having smaller tumor sizes, indicating that distance and tumor characteristics significantly impact patient adherence to recommended imaging surveillance.

Article Abstract

Objective: Imaging surveillance with serial MRI, or a "wait-and-scan" approach, is a management option for patients with small or medium-sized vestibular schwannomas (VSs). Prior publications have indicated no distinct quality of life advantage to upfront treatment compared with initial wait-and-scan management. However, imaging surveillance is dependent on patient adherence to follow-up. In this study, the authors aimed to identify rates and predictors of patient loss to follow-up during wait-and-scan management of sporadic VS.

Methods: A single-center study was conducted including all patients from 2013 to 2018 who had undergone upfront imaging surveillance of sporadic VS. Patient data were retrospectively obtained from the electronic medical record. Outcomes of interest included loss to follow-up unrelated to death and inconsistent adherence to imaging surveillance recommendations. Logistic regression analyses were conducted to evaluate factors associated with loss to follow-up.

Results: Over a 6-year study period, 270 patients underwent initial imaging surveillance of a sporadic VS. The median tumor diameter was 8.6 mm (range 1-28.9 mm). At the time of censoring, 106 patients (39.3%) had received treatment, 157 (58.1%) had been advised to continue follow-up, and 7 (2.6%) had died of non-VS-related causes. In total, 73 patients (27.0%) were completely lost to follow-up prior to the first treatment or death. Additionally, 60 patients (22.2%) missed at least 1 MRI follow-up or imaging follow-up was delayed by more than 1 year. Multivariable logistic regression identified an out-of-state residence (OR 3.05, 95% CI 1.58-5.89, p = 0.0009) and a smaller tumor size (unit OR per 1-mm increase in size, OR 0.88, 95% CI 0.83-0.95, p = 0.0006) to be associated with loss to follow-up. Patients living ≥ 350 miles from the hospital or with tumors ≤ 3 mm at the time of initial clinic evaluation were most likely to be lost to follow-up. Only a smaller tumor size was associated with an increased risk of inconsistent imaging follow-up (unit OR per 1-mm increase in size, OR 0.92, 95% CI 0.87-0.98, p = 0.007).

Conclusions: Patients undergoing imaging surveillance of VS are at risk for loss to follow-up and inconsistent imaging surveillance. Patients with smaller tumors or those living farther away from the treating institution are at highest risk for being lost to follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2024.6.JNS232904DOI Listing

Publication Analysis

Top Keywords

imaging surveillance
32
loss follow-up
20
follow-up
13
lost follow-up
12
imaging
10
patients
9
rates predictors
8
vestibular schwannomas
8
undergoing imaging
8
surveillance
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!