From age-specific to size-specific dose protocol for paediatric head computed tomography: a simple practical strategy for necessity assessment and parameter setting.

Radiat Prot Dosimetry

Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, 1678 Dongfang Road, Shanghai 200127, China.

Published: December 2024

AI Article Synopsis

  • This study evaluates how to effectively transition from age-specific to size-specific dose protocols in pediatric head CT scans for better safety and efficacy.
  • It uses existing age-specific dose protocols for children aged 1 to 6 years (21.34 mGy) and those older than 6 (34.73 mGy), assessing different size groups based on head diameter.
  • Findings indicate that children in one group may have received excessive radiation (38% more than needed), highlighting the importance of tailoring doses based on size rather than just age.

Article Abstract

This study proposes a practical approach to assessing the need for and determining the transitioning parameters from age-specific to size-specific dose protocols in paediatric head computed tomography examinations. It was designed to begin with the two different age-specific protocols currently applied on paediatric patients of 1 y ≤ age ≤ 6 y (21.34 mGy) and those of age >6 y (34.73 mGy). One characteristic size (HDthreshold) was found by measuring anteroposterior head diameter on historical topograms and used with age to set 135 cases into four groups for investigation (A, ≤6y, ≤HDthreshold; B, ≤6y, >HDthreshold; C, >6y, ≤HDthreshold; and D, >6 y, >HDthreshold). The image quality was compared in both subjective and objective manners. Results suggest patients in Group C may have received a potential overdose (38%), while the exposure setting for Group D may replace that for B. The proposed strategy was sufficient to assess the necessity and determine the transitioning parameters from age- to size-specific dose protocols.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncae202DOI Listing

Publication Analysis

Top Keywords

size-specific dose
12
age-specific size-specific
8
paediatric head
8
head computed
8
computed tomography
8
transitioning parameters
8
dose protocols
8
dose protocol
4
protocol paediatric
4
tomography simple
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!