In cardiac surgery, precision and efficiency are crucial, especially in managing venous drainage flows during complex procedures. This practical technique evaluates the benefits of placing the proximal junction on the cardiopulmonary bypass (CPB) side rather than on the surgical table in bicaval cannulation. Bicaval cannulation, involving both the superior vena cava (SVC) and inferior vena cava (IVC), ensures efficient venous return. Placing the junction on the CPB side allows for accurate, real-time control of venous drainage, allowing for swift responses to fluctuations and maintaining stable hemodynamics. This approach could minimize the risk of congestion in the liver, splanchnic system, and cerebral venous return, thereby preventing related complications. Another important potential benefit of this approach could be the ability to closely monitor and manage metabolic demands and oxygen consumption for SVC and IVC. Additionally, EmTec flow technology can be integrated for more precise management.

Download full-text PDF

Source
http://dx.doi.org/10.1177/02676591241295576DOI Listing

Publication Analysis

Top Keywords

vena cava
12
bicaval cannulation
12
cpb side
12
inferior vena
8
drainage flows
8
proximal junction
8
venous drainage
8
venous return
8
selective monitoring
4
monitoring superior
4

Similar Publications

Engineered hiPSC-derived vascular graft brings hope for thrombosis-free vascular therapy.

Cell Stem Cell

January 2025

Department of Chemical and Biological Engineering, University of Wisconsin-Madison, Madison, WI, USA. Electronic address:

Tissue-engineered vascular conduits (TEVCs) are a promising blood vessel replacement. In a recent publication in Cell Stem Cell, Park et al. developed TEVCs comprised of decellularized human umbilical arteries lined with shear-trained, human induced pluripotent stem cell (hiPSC)-derived endothelial cells (ECs) that resisted thrombosis and exhibited patency upon grafting into the rat inferior vena cava (IVC).

View Article and Find Full Text PDF

Transjugular transcatheter edge-to-edge mitral valve repair in a patient with functional mitral regurgitation: a case report.

Eur Heart J Case Rep

January 2025

Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.

Background: Transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is primarily performed using the transfemoral approach. However, when this approach is not feasible, the transjugular approach can be used as an alternative.

Case Summary: A 57-year-old man presented with heart failure and persistent New York Heart Association class IV symptoms, refractory to guideline-directed medical therapy, intravenous therapy, and intra-aortic balloon pumping.

View Article and Find Full Text PDF

Patients at high risk of deep vein thrombosis are recommended to undergo lower-extremity ultrasonography to screen for pulmonary embolism (PE); however, there are few reports on whether this can effectively reduce the occurrence of fatal pulmonary embolism (FPE). This study aimed to assess the risk factors associated with PE and to investigate whether perioperative ultrasound screening of lower extremity veins in orthopedic patients can effectively reduce the incidence of FPE. We enrolled 137 patients with PE who underwent orthopedic surgery between 2013 and 2020.

View Article and Find Full Text PDF

We demonstrate an aberrant ramification pattern of the renal and testicular vessels. On both sides, the anterior and posterior renal veins emerged from the renal. On the right side, the anterior renal vein collected the right testicular vein and drained into the inferior vena cava, while the posterior one directly drained into the inferior vena cava.

View Article and Find Full Text PDF

Introduction: There is a risk of iatrogenic vascular injuries during robotic-assisted laparoscopic excision of diaphragmatic endometriosis. Although studies are limited, the first reported case of a suprahepatic inferior vena cava (IVC) injury during robotic diaphragmatic endometriosis excision was successfully treated using a fibrin sealant patch, preventing exsanguination and conversion to laparotomy.

Case Description: A 36-year-old female with a history of recurrent catamenial pneumothorax and two prior video-assisted thoracoscopic surgeries to treat diaphragmatic endometriosis presented to our clinic with right-sided shoulder pain and a chest tube in place.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!