Echocardiographic quantification of mitral regurgitation (MR) remains challenging, requiring dedicated image acquisition, and is limited by potential error from geometric assumptions of annular dimensions. Volume is a product of area and flow and assuming proportional mitral/aortic areas, an increased mitral-inflow volume compared to LV/RV-outflow semi-quantitatively represents greater MR regurgitant volume. Therefore, we investigated the feasibility and diagnostic performance of the mitral-aortic velocity-time integral(VTI) ratio in isolated MR. We also investigated the use of the mitral-pulmonary VTI ratio as an alternative in clinical situations where the LV outflow tract(LVOT) VTI could not be used. We reviewed 166 consecutive patients (33%, n = 54 severe MR by multi-parameter integrated expert opinion). Pulsed wave Doppler VTI at the mitral leaflet tips and the left ventricular outflow and continuous-wave Doppler of the RV outflow tract were measured individually and independently by blinded readers(expert and trainee status) to derive the ratio. Receiver operator characteristic area under the curve(AUC) comparison was calculated and compared with effective regurgitant orifice area(EROA > 40 mm), regurgitant volume(RVol > 60mL), vena contracta(VC > 0.7 cm), E-velocity > 1.2 cm, systolic flow reversal(SFR), left atrial and ventricular dilatation. Increasing ratio was associated with severe MR(AUC 0.94) with optimal threshold defined at 1.3. This provided significant discrimination for severe MR(AUC 0.81) compared to EROA(0.68), VC(0.52), LV dilatation(0.69), LA dilatation(0.70), SFR(0.73), E-velocity(0.68) all p < 0.05, with sensitivity 82% and specificity 94%. The mitral-pulmonary VTI ratio demonstrated similar discrimination(AUC 0.92) with optimal threshold defined at 1.14. Excellent inter-observer reproducibility(intra-class correlation 0.97) was seen between trainee and expert readers. There was no difference in AUC comparison by MR mechanism or patient rhythm. The mitral-aortic and mitral-pulmonary VTI ratios are simple, geometric-free parameters feasibly reproducible from routine echocardiographic datasets and are excellent discriminative tools for severe MR. Readers should consider integration of this parameter in routine reporting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11618309PMC
http://dx.doi.org/10.1007/s10554-024-03249-xDOI Listing

Publication Analysis

Top Keywords

mitral regurgitation
8
severe mrauc
8
ratio
5
mitral
4
mitral aortic/pulmonary
4
aortic/pulmonary velocity-time
4
velocity-time integral
4
integral ratio
4
ratio simple
4
simple feasible
4

Similar Publications

Biventricular Dysfunction Due to Chronic Mitral Valve Regurgitation Caused by Aberrant Mitral Arcade.

Ann Thorac Surg Short Rep

December 2024

Division of Cardiac Surgery, Department of Surgery, Thomas Jefferson University, Philadelphia, Pennsylvania.

A 53-year-old male individual with chronic severe mitral regurgitation presented with biventricular dysfunction, pulmonary hypertension, and atrial fibrillation. Echocardiography demonstrated a posterior leaflet prolapse with malcoaptation. Mitral valve repair and Maze procedure were performed, revealing absent chordae and direct connection from the anterolateral papillary muscle to the posterior leaflet, consistent with partial mitral arcade.

View Article and Find Full Text PDF

Purpose: To report the outcomes of the early feasibility study of transapical transcatheter mitral valve replacement (TMVR) with the SATURN System (InnovHeart, Milano, Italy) to treat patients with severe functional mitral regurgitation.

Description: Five high surgical risk patients underwent transapical transcatheter mitral valve replacement with the SATURN System at a single center. One-year follow-up is complete for all patients.

View Article and Find Full Text PDF

We report a case of a woman who underwent mitral ring and tricuspid annuloplasty. Two months later, she presented with acute heart failure secondary to severe aortic regurgitation, which was a complication of the cardiac surgery. Given the high surgical risk of reoperation in this the patient, she underwent transcatheter aortic valve implantation, with a good result.

View Article and Find Full Text PDF

Background: Tricuspid valve surgical procedures (TVS) concomitant with mitral valve (MV) surgical procedures for less than severe tricuspid regurgitation (TR) remains controversial. This study examined the long-term outcomes of patients with moderate or mild to moderate TR undergoing MV surgical procedures with or without TVS.

Methods: Patients with moderate or mild to moderate TR undergoing MV replacement or repair between January 2002 and June 2021 were included.

View Article and Find Full Text PDF

Incidentally Discovered Anomalous Mitral Chordae at the Time of Mitral Valve Repair.

Ann Thorac Surg Short Rep

September 2024

Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota.

Anomalous supravalvular mitral chordae tendineae that originate from the mitral leaflet(s) and attach to the interatrial septum or dome of the left atrium are a rare congenital anomaly. These supravalvular chordae are often associated with severe mitral regurgitation and surgical experience has included resection of the anomalous chord as part of the repair. We describe an unusual presentation of an incidentally discovered anomalous supravalvular chord at the time of mitral valve repair for degenerative mitral regurgitation related to a flail posterior leaflet.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!