Integration of paper-based analytical devices with digital microfluidics for colorimetric detection of creatinine.

Analyst

Instituto de Química, Universidade Federal de Goiás - UFG, 74690-900, Goiânia, GO, Brazil.

Published: December 2024

Digital microfluidics (DMF) is a platform that enables the automated manipulation of individual droplets of sizes ranging from nanoliter to microliter and can be coupled with numerous techniques, including colorimetry. However, although the DMF electrode architecture is highly versatile, its integration with different analytical methods often requires either changes in sample access, top plate design, or the integration of supplementary equipment into the system. As an alternative to overcome these challenges, this study proposes a simple integration between paper-based analytical devices (PADs) and DMF for automated and eco-friendly sample processing aiming at the colorimetric detection of creatinine (CR, an important biomarker for kidney disease) in artificial urine. An optimized and selective Jaffé reaction was performed on the device, and the reaction products were delivered to the PAD, which was subsequently analyzed with a bench scanner. The optimal operational parameters on the DMF platform were a reaction time of 45 s with circular mixing and image capture after 5 min. Under optimized conditions, a linear behavior was obtained for creatinine concentrations ranging from 2 to 32 mg dL, with limits of detection and quantitation equal to 1.4 mg dL and 2.0 mg dL, respectively. For the concentration range tested, the relative standard deviation varied from 2.5 to 11.0%, considering four measurements per concentration. CR-spiked synthetic urine samples were subjected to analysis DMF-PAD and the spectrophotometric reference method. The concentrations of CR determined using both analytical techniques were close to the theoretical values, with the resultant standard deviations of 2-9% and 1-4% for DMF-PADs and spectrophotometry, respectively. Furthermore, the recovery values were within the acceptable range, with DMF-PADs yielding 96-108% and spectrophotometry producing 95-102%. Finally, the greenness of the DMF-PAD and spectrophotometry methods was evaluated using the Analytical Greenness (AGREE) metric software, in which 0.71 and 0.51 scores were obtained, respectively. This indicates that the proposed method presents a higher greenness level, mainly due to its miniaturized characteristics using a smaller volume of reagent and sample and the possibility of automation, thus reducing user exposure to potentially toxic substances. Therefore, the DMF-PADs demonstrated great potential for application in the clinical analysis of creatinine, aiding in routine tests by introducing an automated, simple, and environmentally friendly process.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d4an00688gDOI Listing

Publication Analysis

Top Keywords

integration paper-based
8
paper-based analytical
8
analytical devices
8
digital microfluidics
8
colorimetric detection
8
detection creatinine
8
dmf platform
8
analytical
5
integration
4
devices digital
4

Similar Publications

Integrated Management of Childhood Illness (IMCI) is a strategy that aims to standardise clinical assessment and treatment of sick children. In this article, we examine the aspirations and unfolding of introducing a revised IMCI strategy in Bangladesh. We carried out ethnographic fieldwork among project implementors and in IMCI health service delivery settings in Kushtia district, including 36 semi-structured interviews with policymakers, programmers and IMCI service providers.

View Article and Find Full Text PDF

The integration of barcode technology with smartphones on paper-based analytical devices (PADs) presents a promising approach to bridging manual detection with digital interpretation and data storage. However, previous studies of 1D barcode approaches have been limited to providing only a "yes/no" response for analyte detection. Herein, a method of using barcode readout for semiquantitative signal detection on PADs has been achieved through the integration of barcode technology with a distance-based measurement concept on PADs.

View Article and Find Full Text PDF

Background: Palliative care aims to improve quality of life for patients with end-stage illnesses by addressing physical, psychological, social and spiritual needs. Early referral to palliative care improves patient outcomes, quality of life and overall survival in a variety type of cancers. This study aimed to assess knowledge, attitudes and perceived benefits of early integration of palliative care among oncology nursing.

View Article and Find Full Text PDF

Background: Adrenaline and glucose are essential biomarkers in human body for maintaining metabolic balance. Abnormal levels of adrenaline and glucose are associated with various diseases. Therefore, it is important to design portable, on-site devices for rapid adrenaline and glucose analysis to safeguard health.

View Article and Find Full Text PDF

This work describes fully integrated multifolding electrochemical paper-based devices (ePADs) for enhanced multiplexed voltammetric determination of heavy metals (Zn(II), Cd(II), and Pb(II)) using tunable passive preconcentration. The paper devices integrate five circular sample preconcentration layers and a 3-electrode electrochemical cell. The hydrophobic barriers of the devices are drawn by pen-plotting with hydrophobic ink, while the electrodes are deposited by screen-printing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!