A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simulating PFAS transport in effluent-irrigated farmland using PRZM5, LEACHM, and HYDRUS-1D models. | LitMetric

AI Article Synopsis

  • * This study aimed to evaluate three models (PRZM5, LEACHM, and HYDRUS-1D) for predicting PFAS distribution in soil at a site in Pennsylvania that has used wastewater effluent for years.
  • * Results showed that while PRZM5 struggled to accurately predict PFOS behavior, LEACHM and HYDRUS-1D effectively captured PFAS retention, highlighting the importance of modeling both unsaturated flow and adsorption at the air-water interface for long-term predictions.

Article Abstract

Application of wastewater effluent to agricultural lands can serve as a sustainable approach to meet irrigation and nutrient needs for crop production. While nitrogen and phosphorous loadings can be effectively managed, concerns have been raised regarding the fate of emerging contaminants, including per- and polyfluoroalkyl substances (PFAS), which are widely detected in wastewater effluent. The objective of this paper was to evaluate the ability of three unsaturated flow and transport models, Pesticide Root Zone Model 5 (PRZM5), LEACHM, and HYDRUS-1D, to predict the distribution of PFAS in the soil profile at the Pennsylvania State University Living Filter site, which has received daily wastewater effluent applications for several decades. The models were modified to include adsorption at the air-water interface (AWI), which has been shown to be an important factor governing PFAS transport and phase distribution in the vadose zone. Simulations showed that PRZM5 did not accurately reproduce the observed perfluorooctanesulfonic acid (PFOS) behavior, which was attributed to the "tipping bucket" approach used for water flow that results in the disappearance of AWI during water flow. In contrast, both LEACHM and HYDRUS-1D captured the observed retention of PFOS and perfluorooctanoic acid (PFOA) over a 50-year simulation period. Due to differences in the approach used to calculate the AWI area, LEACHM predicted greater accumulation of PFOS and PFOA at the AWI compared to HYDRUS-1D. These findings indicate that mathematical models that directly account for unsaturated water flow and adsorption at the AWI are able to provide reasonable predictions of long-term PFAS leaching resulting from land application of wastewater effluent.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jeq2.20639DOI Listing

Publication Analysis

Top Keywords

wastewater effluent
16
leachm hydrus-1d
12
water flow
12
pfas transport
8
przm5 leachm
8
application wastewater
8
awi
5
simulating pfas
4
transport effluent-irrigated
4
effluent-irrigated farmland
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!