A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An approach for coherent periodogram averaging of tilt-series data for improved CTF estimation. | LitMetric

An approach for coherent periodogram averaging of tilt-series data for improved CTF estimation.

bioRxiv

Department of Biochemistry and Center for Structural Biology, Vanderbilt University, Nashville TN, USA.

Published: October 2024

AI Article Synopsis

  • Cryo-electron microscopy (cryo-EM) is a key method for visualizing the 3D structures of biological molecules, but it faces challenges with distortions caused by the contrast transfer function (CTF).
  • The CTF can degrade image quality, especially with tilt-series data in cryo-electron tomography (cryo-ET), where the specimen tilt creates complex defocus patterns and low signal levels.
  • A new algorithm improves CTF estimation by dividing each tilted image into patches that are adjusted for their defocus shifts, enhancing the visibility of important features and boosting resolution in the final reconstructions.

Article Abstract

Cryo-electron microscopy (cryo-EM) has become an indispensable technique for determining three-dimensional structures of biological macromolecules. A critical aspect of achieving high-resolution cryo-EM reconstructions is accurately determining and correcting for the microscope's contrast transfer function (CTF). The CTF introduces defocus-dependent distortions during imaging; if not properly accounted for, the CTF can distort features in and limit the resolution of 3D reconstructions. For tilt-series data used in cryo-electron tomography (cryo-ET), CTF estimation becomes even more challenging due to the tilt of the specimen, which introduces a defocus gradient across the field of view, as well as the low dose and signal in individual tilt images. Here, we describe a simple algorithm to improve the accuracy of CTF estimation of tilted images by leveraging the tilt-series alignment parameters determined for tomographic reconstruction to explicitly account for the tilted specimen geometry. In brief, each tilt image is divided into patches, each of which are then stretched according to their defocus shift. These are then summed to provide a coherent power spectra at the tilt axis, which can then be used in standard CTF estimation algorithms. This uses all the data in each image to enhance the visibility of Thon rings, thereby improving high-resolution CTF estimation and subsequent enhancements in the resolution of subtomogram averages.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11482968PMC
http://dx.doi.org/10.1101/2024.10.10.617684DOI Listing

Publication Analysis

Top Keywords

ctf estimation
20
tilt-series data
8
ctf
8
estimation
5
approach coherent
4
coherent periodogram
4
periodogram averaging
4
averaging tilt-series
4
data improved
4
improved ctf
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!