Acute iodinate contrast medium reaction: look at the CT images!

Clin Exp Emerg Med

Department of Diagnostic and Interventional Neuroradiology, E.O. Ospedali Galliera, Genoa, Italy.

Published: October 2024

Download full-text PDF

Source
http://dx.doi.org/10.15441/ceem.24.295DOI Listing

Publication Analysis

Top Keywords

acute iodinate
4
iodinate contrast
4
contrast medium
4
medium reaction
4
reaction images!
4
acute
1
contrast
1
medium
1
reaction
1
images!
1

Similar Publications

Background: Triple rule-out computed tomography angiography (CTA) provides imaging of the coronary arteries, pulmonary arteries, and thoracic aorta filled with contrast material (CM) to exclude or diagnose the pathologies of these three systems. Although dual rule-out adapted to exclude aortic and pulmonary pathologies. Iodinated CM may result in contrast-induced nephropathy, which lengthens hospital stay.

View Article and Find Full Text PDF

To evaluate dual-layer dual-energy computed tomography (dlDECT)-based characterization of thrombus composition for differentiation of acute pulmonary embolism (PE) and chronic thromboembolic pulmonary hypertension (CTEPH). This retrospective single center cohort study included 49 patients with acute PE and 33 patients with CTEPH who underwent CT pulmonary angiography on a dlDECT from 06/2016 to 06/2022. Conventional images), material specific images (virtual non-contrast [VNC], iodine density overlay [IDO], electron density [ED]), and virtual monoenergetic images (VMI) were analyzed.

View Article and Find Full Text PDF

Background: The estimated incidence of pulmonary embolism (PE) is around 60-70 cases per 100,000 people annually. The overall mortality rate for massive PE is substantial, ranging from 18% to 65%. We can utilise changes in lung perfusion to stratify patients with PE acutely based on risk, highlighting its diagnostic and prognostic value.

View Article and Find Full Text PDF

Background: Contrast-induced nephropathy (CIN) defined as an acute kidney injury following the administration of iodinated contrast medium (CM). Hysterosalpingography (HSG) is a radiologic procedure used to investigate the shape and structure of the uterine cavity and the patency of the fallopian tubes in the evaluation of infertility. To date, there have been no reports evaluating the development of CIN after HSG procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!