A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of adalimumab by HPLC with fluorescence detection using the König reaction. | LitMetric

Determination of adalimumab by HPLC with fluorescence detection using the König reaction.

Talanta

Graduate School of Pharmaceutical Sciences, Chiba University, 1-8-1 Inohana, Chuo, Chiba, Chiba, 60-8675, Japan. Electronic address:

Published: January 2025

Monoclonal antibody drugs (mAb) are widely used to treat various diseases. Keeping quality of mAbs is crucial to maximize efficacy and minimize adverse effects. To this end, mAb content in the drug product must be precisely quantified. As methods for the determination of mAbs, absorbance measurement at 280 nm, the ligand binding assay based on ELISA, or the LC-MS/MS method based on the surrogate peptide approach is usually used. However, these methods have drawbacks in terms of selectivity, reliability, and cost, respectively. The present method is based on the surrogate peptide approach where a peptide specific to the mAb is determined by a post-column derivatization LC system with fluorescence detection and the König reaction, which is usually used for the detection of cyanide and its derivatives. The detection mechanism was the production of cyanide from the surrogate peptide by chloramine T and the generated cyanide was detected by the König reaction. In this study, adalimumab was used as a model target protein. The calculated LOD and LOQ of the present method were 0.31 μg/mL and 0.94 μg/mL, respectively. The intra-day accuracies and precisions were 127.1 % and 2.94 % for 5 μg of adalimumab and 101.6 % and 10.2 % for 50 μg of adalimumab, respectively. The inter-day accuracies and precisions were 121.8 % and 5.71 % for 5 μg of adalimumab and 101.8 % and 6.98 % for 50 μg of adalimumab, respectively. Our quantitatively determined amount of adalimumab in Humira® was in good agreement with the specified value. This method only requires a conventional LC system, not an LC-MS/MS system. By extending the application of the König reaction, we open the door to a new surrogate peptide approach for the determination of proteins including monoclonal antibody drugs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2024.127044DOI Listing

Publication Analysis

Top Keywords

könig reaction
16
surrogate peptide
16
peptide approach
12
fluorescence detection
8
detection könig
8
monoclonal antibody
8
antibody drugs
8
method based
8
based surrogate
8
accuracies precisions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!