A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surface morphology and chemical composition analysis of titanium dental implants using SEM and EDX. | LitMetric

Surface morphology and chemical composition analysis of titanium dental implants using SEM and EDX.

Bioinformation

Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, KSA.

Published: August 2024

The chemical content and surface morphology of titanium implants have a greater impact on the osseointegration characteristic of dental implants. Therefore this study was done to examine the surface morphology and chemical composition of commercially available titanium dental implants. (BioLine Dental Implants Series-single piece (A) and spiral implants (B)). The chemical composition was determined by the Energy Dispersive X-ray Spectroscopy (EDX) method and the surface morphology was performed by Scanning Electron Microscopy (SEM) method. The results for chemical composition of titanium implants using EDX method revealed that titanium (Ti) constitutes the major surface components on the plain and top land area of the single piece compressive implants which is 89.71 weight% and 71.55 weight % respectively. Iron (Fe)-66.60 weight % is considered as major element along with chromium (Cr)-18.34 weight %on the plain area of spiral implants and O (19.90 weight %) and Al (12.43 weight %) on the top land area of spiral implants. The surface morphology and impact of the manufacturing process on the implant surface using SEM method revealed that the similar surface irregularities with diameter ranging from 10 µm to 20 µm on the side view of the top land area and diameter of 10 µm on the side view of plain area for both the samples. Sample A showed some amorphous structures with grainy marks on the apical view whereas Sample B showed heavy grinding and shear marks on the apical view at diameter ranging from 10 µm to 20µm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11471401PMC
http://dx.doi.org/10.6026/973206300200926DOI Listing

Publication Analysis

Top Keywords

surface morphology
20
chemical composition
16
dental implants
16
spiral implants
12
top land
12
land area
12
implants
10
surface
8
morphology chemical
8
titanium dental
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!