A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An assessment of the inter-rater and intra-rater reliability of the modified Gordon pin infection classification system. | LitMetric

Objectives: A grading system deployed for continuous at-home monitoring of pin sites would potentially increase the chances of early detection of pin-site infections and the commencement of early treatment. The first five grades of the Modified Gordon Pin Site Classification Scheme (MGS) meet the criteria for a visual-only, digital assessment-based grading system. The aim of this study was to assess the inter- and intra-rater reliability of the first five grades of the MGS from digital images.

Methods: We graded 1082 pin sites from 572 digital photographs of patients who underwent external fixator treatment for various conditions using the first five grades of the MGS classification scheme. Percent agreement and kappa values were calculated to determine the inter- and intra-rater agreement. Results were also grouped into two categories: "good" consisting of MGS grades 0-2 and "bad" made up of grades 3 and 4 for sensitivity analysis. We also analyzed reliability based on color only using MGS grades 0 and 2.

Results: A total of 843 of the 1082 pin sites were scored by all raters. There was moderate reliability between raters with a Fleiss kappa value of 0.48 [CI 0.45, 0.51]. The reliability remained moderate based on grouping into "good' versus "bad" and based on color with Fleiss kappa values of 0.48 [CI 0.45, 0.52] and 0.45 [CI 0.42, 0.49], respectively. Intra-rater reliability demonstrated substantial agreement with kappa values of 0.63.

Conclusion: Scoring pin sites from digital images with the MGS demonstrated only moderate inter-rater reliability. Modifying the use of digital photos is needed for at-home monitoring of pin sites.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11475116PMC
http://dx.doi.org/10.1177/20552076241277672DOI Listing

Publication Analysis

Top Keywords

pin sites
20
intra-rater reliability
12
kappa values
12
modified gordon
8
gordon pin
8
grading system
8
at-home monitoring
8
monitoring pin
8
classification scheme
8
inter- intra-rater
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!