Thermal videos provide a privacy-preserving yet information-rich data source for remote health monitoring, especially for respiration rate (RR) estimation. This paper introduces an end-to-end deep learning approach to RR measurement using thermal video data. A detection transformer (DeTr) first finds the subject's facial region of interest in each thermal frame. A respiratory signal is estimated from a dynamically cropped thermal video using 3D convolutional neural networks and bi-directional long short-term memory stages. To account for the expected phase shift between the respiration measured using a respiratory effort belt vs. a facial video, a novel loss function based on negative maximum cross-correlation and absolute frequency peak difference was introduced. Thermal recordings from 22 subjects, with simultaneous gold standard respiratory effort measurements, were studied while sitting or standing, both with and without a face mask. The RR estimation results showed that our proposed method outperformed existing models, achieving an error of only 1.6 breaths per minute across the four conditions. The proposed method sets a new State-of-the-Art for RR estimation accuracy, while still permitting real-time RR estimation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11479072 | PMC |
http://dx.doi.org/10.3390/s24196386 | DOI Listing |
Sensors (Basel)
December 2024
Centre for Sleep Medicine Kempenhaeghe, 5590 AB Heeze, The Netherlands.
Continuous respiration monitoring is an important tool in assessing the patient's health and diagnosing pulmonary, cardiovascular, and sleep-related breathing disorders. Various techniques and devices, both contact and contactless, can be used to monitor respiration. Each of these techniques can provide different types of information with varying accuracy.
View Article and Find Full Text PDFAnn Surg Oncol
January 2025
Center for Liver and Pancreatobiliary Cancer, National Cancer Center, Goyang-si, Korea.
Background: Anatomical liver resection has been altered by a deeper understanding of the internal structure of the liver, highlighting the importance of the intersegmental plane, a region lacking Glissonean branches. These insights have enabled a novel surgical technique focused on the precise detachment of the intersegmental plane, supported by indocyanine green (ICG) fluorescent imaging and robotic platforms, enhancing the precision and safety of liver resection.
Methods: This study involved four patients who underwent robotic left hepatectomy using the Da Vinci Xi system.
Sci Rep
December 2024
Agricultural Engineering Department, Faculty of Agriculture and Natural Resources, Aswan University, Aswan, 81528, Egypt.
Efficient cooling systems are critical for maximizing the electrical efficiency of Photovoltaic (PV) solar panels. However, conventional temperature probes often fail to capture the spatial variability in thermal patterns across panels, impeding accurate assessment of cooling system performance. Existing methods for quantifying cooling efficiency lack precision, hindering the optimization of PV system maintenance and renewable energy output.
View Article and Find Full Text PDFZebrafish
December 2024
Department of Life Sciences and Biotechnology, Faculty of Biology, University of Ferrara, Ferrara, Italy.
Photoperiod and temperature are two of the most powerful environmental cues that entrain circadian clocks. Being ectothermic, fish must keep their body temperature within a physiological range to optimize biological processes mainly applying behavioral strategies. Here, we developed a low-cost, automated system that allows to create a horizontal multiple-step thermal gradient and video record fish behavior for long-term periods.
View Article and Find Full Text PDFJ Bone Joint Surg Am
December 2024
Jack Hughston Memorial Hospital, Phenix City, Alabama.
Background: Operative fires are rare but unforgettable events, with the potential for devastating outcomes. It is estimated that 650 operating room (OR) fires occur each year in the United States, with the use of electrocautery devices and polymethylmethacrylate (PMMA) as the primary ignition and fuel sources. There are several case reports of OR fires caused by PMMA and electrocautery in the literature, but, to our knowledge, no formal studies have been performed exposing the flammability of PMMA and how PMMA reacts to an electrocautery ignition source.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!