A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fibre Refractometry for Minimally Invasive Sugar Content Measurements within Produce. | LitMetric

Fibre Refractometry for Minimally Invasive Sugar Content Measurements within Produce.

Sensors (Basel)

IMEC the Netherlands, OnePlanet Research Center, Bronland 10A, 6708 WH Wageningen, The Netherlands.

Published: September 2024

A minimally invasive needle refractometer is presented for sugar content measurements within produce. A passive sampling cap structure was developed that improves the reliability of the device by avoiding interfering back reflections from the flesh of the produce. It is explained that factory calibration may not be needed for this type of refractometer, potentially reducing production costs. Also demonstrated is an iterative method to correct for temperature variations without the need for an integrated model for how the refractive index changes with temperature for different levels of sugar concentration. The sensor showed a typical standard deviation of 0.4 °Bx for a 10-s-long measurement and was validated against a prism refractometer, showing an average offset of (0.0±0.1) °Bx. In addition, the potential for using the device to investigate sugar distributions within a single fruit sample is demonstrated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11479293PMC
http://dx.doi.org/10.3390/s24196336DOI Listing

Publication Analysis

Top Keywords

minimally invasive
8
sugar content
8
content measurements
8
measurements produce
8
fibre refractometry
4
refractometry minimally
4
sugar
4
invasive sugar
4
produce minimally
4
invasive needle
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!