A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stereo Bi-Telecentric Phase-Measuring Deflectometry. | LitMetric

Stereo Bi-Telecentric Phase-Measuring Deflectometry.

Sensors (Basel)

State Key Laboratory of Precision Measuring Technology and Instruments, Laboratory of Micro/Nano Manufacturing Technology, Tianjin University, Tianjin 300072, China.

Published: September 2024

Replacing the endocentric lenses in traditional Phase-Measuring Deflectometry (PMD) with bi-telecentric lenses can reduce the number of parameters to be optimized during the calibration process, which can effectively increase both measurement precision and efficiency. Consequently, the low distortion characteristics of bi-telecentric PMD contribute to improved measurement accuracy. However, the calibration of the extrinsic parameters of bi-telecentric lenses requires the help of a micro-positioning stage. Using a micro-positioning stage for the calibration of external parameters can result in an excessively cumbersome and time-consuming calibration process. Thus, this study proposes a holistic and flexible calibration solution for which only one flat mirror in three poses is needed. In order to obtain accurate measurement results, the calibration residuals are utilized to construct the inverse distortion map through bicubic Hermite interpolation in order to obtain accurate anchor positioning result. The calibrated stereo bi-telecentric PMD can achieve 3.5 μm (Peak-to-Valley value) accuracy within 100 mm (Width) × 100 mm (Height) × 200 mm (Depth) domain for various surfaces. This allows the obtaining of reliable measurement results without restricting the placement of the surface under test.

Download full-text PDF

Source
http://dx.doi.org/10.3390/s24196321DOI Listing

Publication Analysis

Top Keywords

stereo bi-telecentric
8
phase-measuring deflectometry
8
bi-telecentric lenses
8
calibration process
8
bi-telecentric pmd
8
micro-positioning stage
8
order accurate
8
calibration
6
bi-telecentric phase-measuring
4
deflectometry replacing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!