Endothelin-1 (ET-1) is a potent vasoconstrictor produced by endothelial cells and cleared from circulating blood mainly in the pulmonary vasculature. In a healthy pulmonary circulation, the rate of local production of ET-1 is less than its rate of clearance. In the present study, we aimed to investigate whether the abnormal pulmonary circulatory handling of ET-1 relates to poor clinical outcomes in patients with coronavirus disease 2019 (COVID-19)-induced acute respiratory distress syndrome (ARDS). To this end, central venous and systemic arterial ET-1 plasma levels were simultaneously measured on Days 1 and 3 following ICU admission in mechanically ventilated COVID-19 patients with ARDS (COVID-19 ARDS, N = 18). Central venous and systemic arterial ET-1 plasma levels were also measured in two distinct SARS-CoV-2-negative mechanically ventilated critically ill patient groups, matched for age, sex, and critical illness severity, with ARDS (non-COVID-19 ARDS, N = 14) or without ARDS (non-COVID-19 non-ARDS, N = 20). Upon ICU admission, COVID-19-induced ARDS patients had higher systemic arterial and central venous ET-1 levels compared to the non-COVID-19 ARDS and non-COVID-19 non-ARDS patients ( < 0.05), yet a normal systemic arterial:central venous (A:V) ET-1 ratio [0.63 (0.49-1.02)], suggesting that pulmonary ET-1 clearance is intact in these patients. On the other hand, the non-COVID-19 ARDS patients demonstrated abnormal ET-1 handling [A:V ET-1 ratio 1.06 (0.93-1.20)], while the non-COVID-19 non-ARDS group showed normal ET-1 handling [0.79 (0.52-1.11)]. On Day 3, the A:V ratio in all three groups was <1. When the COVID-19 ARDS patients were divided based on 28-day ICU mortality, while their systemic arterial and central venous levels did not differ, the A:V ET-1 ratio was statistically significantly higher upon ICU admission in the non-survivors [0.95 (0.78-1.34)] compared to the survivors [0.57 (0.48-0.92), = 0.027]. Our results highlight the potential importance of ET-1 as both a biomarker and a therapeutic target in critically ill COVID-19 patients. The elevated A:V ET-1 ratio in non-survivors suggests that the early disruption of pulmonary ET-1 handling may be a key marker of poor prognosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11476705 | PMC |
http://dx.doi.org/10.3390/ijms251910640 | DOI Listing |
J Vasc Access
December 2024
Clinical Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.
The fibroblastic sleeve is a structure potentially enveloping any intravascular device. At ultrasound scan, it typically presents as a thin layer of variably echogenic material covering the catheter surface, which usually tends to remain into the vessel after the catheter removal. However, several case reports have documented its migration toward the heart or pulmonary artery after a central venous catheter removal.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
December 2024
Department of Pulmonary and Critical Care Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, 510080, Guangdong, China.
Epidemiol Mikrobiol Imunol
December 2024
Objective: The aim of our study was to describe and analyze HAI incidence, etiology and risk factors in pediatric intensive care unit (ICU).
Background: Intensive care patients are at high risk of hospital-acquired infections (HAI) due to their underlying diseases and exposure to invasive devices.
Methods: The study group consisted of patients admitted to children's hospital ICU for more than 2 days during a six-month period (267 patients, 1570 patient-days).
Invest Radiol
October 2024
From the Department of Radiology and Nuclear Medicine, UKSH Lübeck, Lübeck, Germany (J.S., M.M., L.B., Y.E., J.B., M.M.S.); Institute of Medical Informatics, University of Lübeck, Lübeck, Germany (L.H., M.P.H.); Philips Research Hamburg, Hamburg, Germany (A.S., H.S.); and Institute of Interventional Radiology, UKSH Lübeck, Lübeck, Germany (M.M.S.).
Purpose: Accurate detection of central venous catheter (CVC) misplacement is crucial for patient safety and effective treatment. Existing artificial intelligence (AI) often grapple with the limitations of label inaccuracies and output interpretations that lack clinician-friendly comprehensibility. This study aims to introduce an approach that employs segmentation of support material and anatomy to enhance the precision and comprehensibility of CVC misplacement detection.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
December 2024
Department of Cardiology, Fukuoka Children's Hospital, 5-1-1, Kashiiteriha, Higashi-Ku, Fukuoka City, Fukuoka, 813-0017, Japan.
Fontan-associated liver disease (FALD) may be caused by chronic liver congestion due to high central venous pressure (CVP). Recently, the usefulness of liver native T1 mapping in magnetic resonance imaging (MRI) in adulthood has been reported. To evaluate the usefulness of native liver T1 mapping in children with congenital heart disease (CHD), we investigated the utility of native liver T1 relaxation time (LT1) in pediatric Fontan patients in comparison to other CHDs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!