Robust Strain Sensor with High Sensitivity Based on Polymer-Encapsulated Microfiber Mach-Zehnder Interferometer.

Polymers (Basel)

Optics and Optoelectronics Laboratory, College of Physics and Optoelectronic Engineering, Ocean University of China, Qingdao 266100, China.

Published: October 2024

A robust strain sensor is demonstrated based on a microfiber Mach-Zehnder interferometer (MMZI) encapsulated by the polymer polydimethylsiloxane (PDMS). Benefiting from the low Young's modulus of PDMS, both a robust structure and high sensitivity can be realized based on three different encapsulations. In the experiment, the proposed sensors are fabricated and tested with strain sensitivities ranging from -20.95 pm/με to 127.00 pm/με within the wavelength range of 1200-1650 nm. Compared with the bare MMZI sensor, at least one order of magnitude higher sensitivity is reached. To further evaluate the performance of the sensor, the dependences of sensitivity on probing wavelength and the different types and quantities of polymers used in encapsulation are discussed. Results show that the sensitivity of the sensor will increase with the probing wavelength. The type and quantity of polymer used are also very critical to sensitivity. Additionally, a response time of 24.72 ms can be reached. Good recoverability and repeatability of the sensor are also demonstrated by repeated experiments. The strain sensor demonstrated here shows the advantages of simple fabrication, robust structure, high and tunable sensitivity, fast response, good recoverability and repeatability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11478986PMC
http://dx.doi.org/10.3390/polym16192810DOI Listing

Publication Analysis

Top Keywords

strain sensor
12
sensor demonstrated
12
robust strain
8
high sensitivity
8
microfiber mach-zehnder
8
mach-zehnder interferometer
8
robust structure
8
structure high
8
probing wavelength
8
good recoverability
8

Similar Publications

The failure of locked-segment landslides is associated with the destruction of locked segments that exhibit an energy accumulation effect. Thus, understanding their failure mode and instability mechanism for landslide hazard prevention and control is critical. In this paper, multiple instruments, such as tilt sensors, pore water pressure gauges, moisture sensors, matrix suction sensors, resistance strain gauges, miniature earth pressure sensors, a three-dimensional (3D) laser scanner, and a camera, were used to conduct the physical model tests on the rainfall-induced arch locked-segment landslide to analyze the resulting tilting deformation and evolution mechanism.

View Article and Find Full Text PDF

Antibiotic-resistant strains of Staphylococcus aureus pose a significant threat in healthcare, demanding urgent therapeutic solutions. Combining bacteriophages with conventional antibiotics, an innovative approach termed phage-antibiotic synergy, presents a promising treatment avenue. However, to enable new treatment strategies, there is a pressing need for methods to assess their efficacy reliably and rapidly.

View Article and Find Full Text PDF

Unlabelled: has numerous two-component signaling systems (TCSs), many of which regulate the complex social behaviors of this soil bacterium. A subset of TCSs consists of NtrC-like response regulators (RRs) and their cognate histidine sensor kinases (SKs). We have previously demonstrated that a multi-component, phosphorelay TCS named NmpRSTU plays a role in social motility.

View Article and Find Full Text PDF

Click chemistry-enabled gold nanorods for sensitive detection and viability evaluation of copper(II)-reducing bacteria.

Mater Today Bio

February 2025

Department of Laboratory Medicine, Zhongshan Hospital, Fudan University, 136 Yi Xue Yuan Road, Shanghai, 200032, PR China.

The rise of antibiotic resistance poses a significant and ongoing challenge to public health, with pathogenic bacteria remaining a persistent threat. Traditional culture methods, while considered the gold standard for bacterial detection and viability assessment, are time-consuming and labor-intensive. To address this limitation, we developed a novel point-of-care (POC) detection method leveraging citrate- and alkyne-modified gold nanorods (AuNRs) synthesized with click chemistry properties.

View Article and Find Full Text PDF

Developing hydrogels with high conductivity and toughness a facile strategy is important yet challenging. Herein, we proposed a new strategy to develop conductive hydrogels by growing metal dendrites. Water-soluble Sn ions were soaked into the gel and then converted to Sn dendrites an electrochemical reaction; the excessive Sn ions were finally removed by water dialysis, accompanied by dramatic shrinkage of the gel.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!