A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of the Mammoth Balloon Catheter in Patients with Severe Aortic Valve Stenosis Undergoing Percutaneous Treatment. | LitMetric

AI Article Synopsis

  • - Balloon aortic valvuloplasty (BAV) is a procedure used for patients with severe aortic valve stenosis, either as preparation for trans-catheter aortic valve replacement (TAVR) or alone in certain cases; the study focused on the newly available Mammoth balloon catheter (BC) used in this context.
  • - A retrospective analysis was conducted on patients treated with the Mammoth BC at a hospital in Milan, where technical success was defined by the ability to successfully deploy and inflate the catheter without significant complications like injury or stroke.
  • - The results showed a 100% technical success rate in 121 procedures with no complications attributed to the Mammoth BC; however, some patients in the stand-alone group

Article Abstract

: Balloon aortic valvuloplasty (BAV) is currently used as pre-treatment for patients undergoing trans-catheter aortic valve replacement (TAVR) as well as a stand-alone option for subjects with significant contraindications to TAVR. Mammoth is a newly available non-compliant balloon catheter (BC) included in the balloon-expandable Myval THV system (Meril Life Sciences Pvt. Ltd., India). As limited data on the performance of this BC are available, we here report the results following its use for BAV as pre-dilatation during TAVR or as a stand-alone procedure. : A retrospective, single-center cohort analysis was performed on patients with severe aortic valve stenosis (AS) treated with the Mammoth BC at IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy. The primary endpoint was technical success defined as successful Mammoth BC advancement across the AS followed by its full and homogeneous inflation without major complications such as aortic root/left ventricular outflow tract injury and/or stroke. : A total of 121 patients were treated by BAV with Mammoth BC during the study period. Among these, 105 patients underwent BAV pre-dilatation before TAVR while 16 patients underwent a stand-alone BAV procedure. Mammoth BC was delivered and successfully inflated at the target site in all of the 121 cases without BC-related complications (100% technical success). However, in the BAV "stand-alone group", three patients required two different balloon sizes while in nine patients multiple rounds (two to three) of balloon inflation were needed to significantly lower the transvalvular gradient. No cases of aortic root injury or massive aortic regurgitation due to Mammoth BC-related aortic leaflet injury were reported while one major stroke occurred late after TAVR. No intra-procedural deaths occurred nor bleeding (BARC 3-4) or major vascular complication. : Mammoth BC use in patients with severe AS proved safe and effective, either before TAVR or as a stand-alone procedure, expanding the range of available tools for structural operators.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11477653PMC
http://dx.doi.org/10.3390/jcm13195986DOI Listing

Publication Analysis

Top Keywords

patients severe
12
aortic valve
12
patients
9
balloon catheter
8
aortic
8
severe aortic
8
valve stenosis
8
bav pre-dilatation
8
pre-dilatation tavr
8
tavr stand-alone
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!