: The aim of this study was to report the visual and refractive outcomes of nanophthalmic eyes undergoing phacoemulsification at a tertiary cataract center. This is a prospective consecutive case series. Patients with an axial length of ≤20.5 mm who underwent phacoemulsification at a tertiary cataract center in Hong Kong were included. Eyes undergoing extracapsular cataract extraction or with a previous history of intraocular surgery including trabeculectomy were excluded. The outcome measures were the corrected distance visual acuity (CDVA) and refractive status at four months post-operation. Different intraocular lens formulas were used to compare the refractive outcomes. Out of 22,847 cataract surgeries performed from May 2011 to March 2020, 14 eyes (0.06%) of 10 patients had axial lengths of ≤20.5 mm and underwent phacoemulsification. The mean axial length was 20.13 ± 0.44 mm. Out of these fourteen eyes, three (21%) had postoperative myopic shift with spherical equivalent refraction of more than or equal to 1D compared to the original target. Eleven eyes (79%) had postoperative refraction within 0.5D compared to the original target. Nine out of fourteen eyes (64%) had improvements in postoperative vision. There were no intraoperative complications. When comparing the Hoffer Q, Holladay 1, Holladay 2, Haigis and Hill-RBF 2.0 formulas, there was no significant difference in the absolute errors between the five formulas ( = 0.072). There was no significant difference in the mean absolute errors between the Hoffer Q, Holladay 1, Holladay 2, Haigis and Hill-RBF 2.0 formulas. Myopic shift was not uncommon, and more studies on intraocular lens (IOL) power calculation for short eyes are warranted.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11477411 | PMC |
http://dx.doi.org/10.3390/jcm13195852 | DOI Listing |
J Clin Med
January 2025
Ophthalmology Section, Department of Medicine and Surgery, University of Perugia, 06132 Perugia, Italy.
To report the cosmetic, clinical, and visual outcomes of a combined surgical approach for treating a corneal/limbal dermoid using excision and a three-layered amniotic membrane graft with fibrin glue. An 18-year-old female presented with impaired vision and ocular discomfort caused by a prominent dome-shaped limbal congenital dermoid on the inferotemporal cornea, resulting in a significant aesthetic concern. A full assessment, including refraction, best-corrected visual acuity (BCVA), corneal topography, aberrometry and anterior segment OCT (AS-OCT) was conducted to plan the surgical approach.
View Article and Find Full Text PDFLife (Basel)
January 2025
Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, 61-553 Poznan, Poland.
To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a prediction error (PE) within ±0.5 D. Data on Caucasian patients who underwent uneventful phacoemulsification between May 2018 and September 2023 in MW-Med Eye Center, Krakow, Poland and Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv, Ukraine were reviewed.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Department of Ophthalmology and Visual Sciences, McGill University, 5252 Maisonneuve Blvd W, 4th floor,, Montreal, Québec, H4A 3S5, Canada.
Objective: To assess refractive and visual outcomes of a spherical Implantable Collamer Lens (ICL) followed by planned postoperative adjunctive laser-assisted in situ keratomileusis (LASIK) in the treatment of high compound hyperopic astigmatism.
Methods: In this prospective, multi-center, multi-surgeon, single-arm trial, eyes with ≥ 3.50 D hyperopia and ≥ 2.
J AAPOS
January 2025
Department of Ophthalmology & Visual Sciences, Washington University School of Medicine, St. Louis, Missouri. Electronic address:
Background: The location of extraocular muscle (EOM) insertions is clinically relevant in ophthalmologic surgery. The spiral of Tillaux has been a reference for normal EOM insertion since the nineteenth century. Research on EOM insertions is limited and has focused on adult cadaveric eyes.
View Article and Find Full Text PDFInt Ophthalmol
January 2025
Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China.
Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formulas in cataract patients with keratoconus (KC).
Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analysis statementand and was registered on PROSPERO (CRD42024568997). Pubmed, Web of Science, Cochrane Library, and EMBASE were searched for retrospective and prospective clinical studies published until October 2024.