A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Enhancing Light-curing Competence: A Study of Radiant Exposure and Training Outcomes Among Dental Students. | LitMetric

Objectives: The aim of this study was to measure radiant exposure and time necessary to deliver 16 J/cm2 of radiant exposure to simulated Class I and Class III preparations by first-year dental students. First-year dental students (n=89) received a 60-minute lecture on light-curing. Using the Managing Accurate Resin Curing Patient Simulator (MARC-PS) and protective blue-light-blocking glasses, students twice light-cured Class I and Class III restorations, using the Valo Grand Cordless light-curing unit with infection-control barriers on both Standard and High Power Plus modes. After their first attempts, if students did not obtain at least 16 J/cm2 of radiant exposure (RE), they received additional instruction. Paired t-tests were used to determine the change between the first and second attempts. After averaging two attempts, radiant exposure and time were compared between Standard and High Power Plus modes within individuals using paired t-tests.

Results: 79% of students provided 16 J/cm2 of radiant exposure on both attempts for Standard and High Power Plus modes. High Power Plus mode provided statistically significantly more radiant exposure and required less time to obtain 16 J/cm2 of radiant exposure for both restorations.

Conclusions: The MARC-PS is useful to identify students requiring instruction. It may be prudent to use High Power Plus mode or increase time on Standard mode to light-cure Class I restorations.

Download full-text PDF

Source
http://dx.doi.org/10.2341/24-003-LDOI Listing

Publication Analysis

Top Keywords

radiant exposure
32
high power
20
j/cm2 radiant
16
dental students
12
standard high
12
power modes
12
radiant
8
exposure
8
exposure time
8
class class
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!