A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Passive fit and time efficiency for prefabricated versus conventionally constructed cobalt chromium CAD\CAM 3-unit implant supported frameworks in free end saddle models: a pilot invitro study. | LitMetric

Passive fit and time efficiency for prefabricated versus conventionally constructed cobalt chromium CAD\CAM 3-unit implant supported frameworks in free end saddle models: a pilot invitro study.

BMC Oral Health

Professor of Prosthodontics and Member of Evidence Based Dentistry Centre, Faculty of Dentistry, Cairo University, Vice Dean of School of Dentistry, Badya University, 11 Al Saraya, Al Manial, Giza Governorate, Cairo, Egypt.

Published: October 2024

Background: The passive fit of 3-unit implant supported prefabricated metal screw-retained prosthesis before implant placement might be difficult. Hence, we aim to evaluate the passive fit and time efficiency of CAD/CAM 3-unit implant supported fixed prostheses that were constructed based on virtual versus those based on actual implant positions in Kennedy Class I models.

Methods: A sample of 5 Kennedy class I models with thin wiry ridges were restored by 20 frameworks bilaterally, 10 based on actual (group A) and 10 based on virtual (group V) implant positions. The models were imaged using cone beam computed tomography and scanned using an intraoral scanner. The STL (Standard Tessellation Language files) and the DICOM (Digital Imaging and Communications in Medicine) files were registered on a 3D planning software. A CAD/CAM surgical guide was planned, resin printed and used for installing 6 implants bilaterally. In group V, the framework was designed based on the virtual scan bodies and virtual multi-unit abutments, while in group A intra-oral scanning of the model after attaching the scan bodies was necessary. Frameworks of both groups were milled and tested for passive fit using 8 clinical tests. McNemar and Wilcoxon signed rank tests were used to study the effect of the group on passive fit and time efficiency, respectively. The significance level was set at P ≤ 0.05.

Results: No statistically significant difference was found between group V and group A frameworks regarding passive fit (p-value = 1, OR = 0.5) and time efficiency (P = 0.179, Effect size = 0.948).

Conclusion: Within the limitations of this study, it can be concluded that in free end saddle cases, prefabricated CAD\CAM 3-unit implant-supported cobalt chromium screw retained prostheses can achieve an adequate passive fit. However, their fit might be negatively affected in thin ridges and they might require some adjustments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11481720PMC
http://dx.doi.org/10.1186/s12903-024-04950-yDOI Listing

Publication Analysis

Top Keywords

passive fit
28
time efficiency
16
fit time
12
3-unit implant
12
implant supported
12
based virtual
12
cobalt chromium
8
cad\cam 3-unit
8
free saddle
8
based actual
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!