Research on capacitance-coupled electrical impedance imaging fusion algorithm based on wavelet transform.

Rev Sci Instrum

School of Mechanical and Precision Instrument Engineering, Xi an University of Technology, No. 5 Jinhuanan Road, Xi'an 710048, People's Republic of China.

Published: October 2024

Capacitively Coupled Electrical Impedance Tomography (CCEIT), as a new electrical tomography method, effectively overcomes the drawbacks of traditional electrical resistance tomography that requires direct contact with liquids, so as to achieve non-contact measurement. In order to make full use of the complete electrical impedance information (real and imaginary) obtained by CCEIT and further improve the quality of image reconstruction, an image fusion algorithm based on wavelet transform was proposed. First, the Landweber algorithm is used to image the real part information and the imaginary part information, and the wavelet transform algorithm is used to decompose the two images at multiple scales, in which the low-frequency coefficient is fused by the improved logic filter algorithm based on the adaptive threshold, the high-frequency coefficient is selected based on the absolute value maximum method for fusion, and finally, the fused image is obtained by wavelet reconstruction. Numerical simulations and experiments verify the feasibility of the proposed method, and the results show that the relative error is reduced by up to 17% and the correlation coefficient is increased by up to 10%.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0218402DOI Listing

Publication Analysis

Top Keywords

electrical impedance
12
algorithm based
12
wavelet transform
12
fusion algorithm
8
based wavelet
8
real imaginary
8
algorithm
5
capacitance-coupled electrical
4
impedance imaging
4
imaging fusion
4

Similar Publications

Advanced control strategy for AC microgrids: a hybrid ANN-based adaptive PI controller with droop control and virtual impedance technique.

Sci Rep

December 2024

Department of Theoretical Electrical Engineering and Diagnostics of Electrical Equipment, Institute of Electrodynamics, National Academy of Sciences of Ukraine, Beresteyskiy, 56, Kyiv-57, Kyiv, 03680, Ukraine.

In this paper, an improved voltage control strategy for microgrids (MG) is proposed, using an artificial neural network (ANN)-based adaptive proportional-integral (PI) controller combined with droop control and virtual impedance techniques (VIT). The control strategy is developed to improve voltage control, power sharing and total harmonic distortion (THD) reduction in the MG systems with renewable and distributed generation (DG) sources. The VIT is used to decouple active and reactive power, reduce negative power interactions between DG's and improve the robustness of the system under varying load and generation conditions.

View Article and Find Full Text PDF

detection suffers from slow analysis time and high costs, along with the need for specificity. While state-of-the-art electrochemical biosensors are cost-efficient and easy to implement, their sensitivity and analysis time still require improvement. In this work, we present a paper-based electrochemical biosensor utilizing magnetic core-shell FeO@CdSe/ZnS quantum dots (MQDs) to achieve fast detection, low cost, and high sensitivity.

View Article and Find Full Text PDF

A Cell-Based Electrochemical Biosensor for the Detection of Infectious Hepatitis A Virus.

Biosensors (Basel)

November 2024

Nano Electrochemistry Laboratory, College of Engineering, University of Georgia, Athens, GA 30602, USA.

Hepatitis A virus (HAV), a major cause of acute liver infections, is transmitted through the fecal-oral route and close contact with infected individuals. Current HAV standardized methods rely on the detection of virus antigen or RNA, which do not differentiate between infectious and non-infectious HAV. The objective of this study was to develop a prototype cell-based electrochemical biosensor for detection of infectious HAV.

View Article and Find Full Text PDF

This scoping review summarizes two emerging electrical impedance technologies: electrical impedance myography (EIM) and electrical impedance tomography (EIT). These methods involve injecting a current into tissue and recording the response at different frequencies to understand tissue properties. The review discusses basic methods and trends, particularly the use of electrodes: EIM uses electrodes for either injection or recording, while EIT uses them for both.

View Article and Find Full Text PDF

It is widely accepted that mobile ions are responsible for the slow electronic responses observed in metal halide perovskite-based optoelectronic devices, and strongly influence long-term operational stability. Electrical characterisation methods mostly observe complex indirect effects of ions on bulk/interface recombination, struggle to quantify the ion density and mobility, and are typically not able to fully quantify the influence of the ions upon the bulk and interfacial electric fields. We analyse the bias-assisted charge extraction (BACE) method for the case of a screened bulk electric field, and introduce a new characterisation method based on BACE, termed ion drift BACE.

View Article and Find Full Text PDF